acura Workshop Repair Guides

Acura (Honda) Workshop Service and Repair Manuals

Radiator Cooling Fan Motor|Testing and Inspection > < Radiator Cooling Fan Motor|Locations
Page 1
background image

Radiator Cooling Fan Motor: Description and Operation

Radiator and condenser fan operation is controlled by the radiator fan control module.

The radiator fan control module is supplied battery voltage at all times through fuse 39. When the ignition switch is in its ON (II) or START (III)
position, voltage is supplied through fuse 4.

When the ignition switch is in ON (II) position, battery voltage is also supplied to the radiator fan control module through fuse 8. The module is
grounded at G401.

The radiator fan control module turns ON the condenser fan and radiator fan for engine and refrigerant cooling whenever the A/C is ON.

If the Engine Coolant Temperature (ECT) is more than 97°C (207°F) when you turn the ignition switch to LOCK (0) the radiator fan control module
will turn ON the radiator fan and let it run for about 15 minutes.

Radiator Fan
Voltage is provided at all times to the radiator fan relay contacts through fuse 38.

The radiator fan control module applies voltage to the radiator fan relay coil. The relay is grounded by ECT switch A when coolant temperature
exceeds 93°C(199°F). The relay is also grounded by the engine control module.

 

Grounding energizes the relay. applying voltage to the radiator fan motor through the WHT wire, the condenser fan relay contacts, and the
WHT/BLU wire.

Radiator Cooling Fan Motor|Testing and Inspection > < Radiator Cooling Fan Motor|Locations