10. Measure the voltage between the No.14 terminal of climate control unit connector A (20P) and body ground.

Is there 5 V or more?

YES - Go to step 11.

NO - Repair the open in the wire between the climate control unit and the A/C pressure switch.

11. Turn the ignition switch OFF.

12. Measure the evaporator sensor resistance between the No.5 and No.18 terminals of climate control unit connector A (20P).

Is the resistance less than 24 KOhms?

YES - Go to step 13.

NO - Repair cause of high resistance in the evaporator temperature circuit.

13. Reconnect climate control unit connector A (20P).
14. Turn the ignition switch ON (II).
15. Check that blower motor operates at all speeds.

Does the blower motor operate at all speeds?

YES - Check for loose wires or poor connections at climate control unit connector A (20P) and at the A/C pressure switch 4P connector. If the
connections are good, substitute a known-good climate control unit and recheck. If the symptom/indication goes away, replace the original climate
control unit.

NO - Repair the problem in the blower motor circuit.

16. Check for proper A/C system pressure.

Is the pressure within specifications

YES - Replace the A/C pressure switch.

NO - Repair the A/C pressure problem.