Instrument Panel Control Module: Customer Interest
Instruments - Incorrect Outside Air Temp. Readings

05-025

August 9, 2005

Applies To: 
2004 TL - ALL

Outside Air Temperature Gauge Reads Inaccurately

SYMPTOM

In certain temperature ranges, the outside air temperature gauge reads several degrees (more than three) higher than expected. Occasionally, the outside
temperature gauge displays three dashes after long cranks (when the engine is hot) and the temperature gauge then resets on the next ignition sequence.

NOTE

If the ambient temperature exceeds 115 °F, the gauge displays three dashes. This is normal.

PROBABLE CAUSE

The gauge control module logic is faulty.

CORRECTIVE ACTION

Replace the gauge control module/combination meter assembly.

PARTS INFORMATION

Gauge Control Module:

A/T - P/N 78100-SEP-305 
M/T - P/N 78100-SEP-307

WARRANTY CLAIM INFORMATION

In warranty: 
The normal warranty applies.

Operation Number:

734101

Flat Rate Time:

0.3 hour

Failed Part:

P/N 78100-SEP-A01

Defect Code:

03214

Symptom Code:

03279

Template ID:

05-025A (A/T) 
05-025B (M/T)

Skill Level:

Repair Technician

Out of warranty: 
Any repair performed after warranty expiration may be eligible for goodwill consideration by the District Parts and Service Manager or your Zone
Office. You must request consideration, and get a decision, before starting work.

REPAIR PROCEDURE

1.

Using the Honda Diagnostic System (HDS), retrieve the odometer value.

^

Refer to page 22-267 of the 2004 - 05 TL Service Manual, or

^

Online, enter keyword ODO, and select