TL AWD V6-3.7L (2010)
Fuel Door Release Actuator: Testing and Inspection
Fuel Fill Door Opener Solenoid Test
1. Open the trunk lid, and remove the left trunk side trim panel See: Trunk / Liftgate/Trunk / Liftgate Interior Trim Panel/Service and Repair/Interior
Trim Removal/Installation - Trunk Area.
2. Disconnect the 2P connector (A) from the fuel fill door opener solenoid (B).
3. Check solenoid operation by connecting power to terminal No. 2 and ground terminal No. 1 momentarily.
NOTE: To prevent damage to the solenoid only apply battery voltage momentarily.
4. If the solenoid does not actuate, replace it.