8. Remove the four screws and the actuator (D) from the actuator housing.
Installation
9. Install new actuator to the housing and visor in the reverse order of step 7 and 8.
10. Route the wire harness (A) of a new actuator through the hole in the seal (B), then tighten a screw (C).
11. Route the wire harness of a new actuator through the hole in the bracket (D).
12. Reassemble the mirror in the reverse order of removal. Apply LOCTITE to the three screws (E) and tighten to 4 N-m (0.4 kgf-m, 3 lbf-ft).
13. Install the gasket in the reverse order of removal.
14. Insert the mirror actuator wires into the original terminal locations as noted in step 4.
NOTE: Be careful to insert the wires correctly because the wires cannot be removed from the coupler once they are inserted.
15. Reassemble in the reverse order of disassembly.
NOTE: Be careful not to break the mirror when reinstalling it to the actuator.
16. Reinstall the mirror assembly on the door.