P0697 - sensor power supply 3
- Make
- Alfa Romeo
- Model
- 159 Factory Service Manual
- Year
- 2005–2011
- Section
- Examiner - diesel electronic management › P0697 - sensor power supply 3
Fault diagnosisP0697 - sensor power supply 3
P0697 - SENSOR POWER SUPPLY 3
The diagnostic equipment signals: Error P0697 (Sensor power supply 3).
This error is detected if there is a short circuit to positive (detail "beyond the upper limit") or a short circuit to earth or a break (detail "below the lower limit") in the circuit connected to Pin 22, or 44 of the junction unit.
| 1 | Junction unit connections check | ALL OK | PROBLEMS ENCOUNTERED | ACTION |
|---|---|---|---|---|
Check that the engine management control unit connections are correct by carrying out the test | End of diagnosis |
Parts & tools for this job For 2005 Alfa Romeo 159