audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

All Technical Service Bulletins for Housing Assembly HVAC: > < Heater Plenum Chamber <--> [Heater Core Case]|Service and Repair|Page 8631
Page 1
background image

Housing Assembly HVAC: Customer Interest
A/C - Water from Air Vents & Moisture in Front Footwell

GROUP: 87
NUMBER: 91-04
DATE: May 31, 1991

SUBJECT:
Water Spray From Air Vents And Moisture In Front Foot Well

MODEL(S):
80/90, V8    M.Y. 1990 - 1991

CONDITION:

A/C drain hose kinked or not fully seated on/in A/C evaporator housing. This condition may allow water to collect in evaporator housing and be forced
out through vents or splash out into front foot wells.

PRODUCTION:

Change of lubrication allows easier assembly of drain hose on evaporator housing.

As of: February 1991

VIN: 8A_MA 190 350

8B_MA 008 387
4C_MN 002 713

SERVICE:

Check placement and seating of drain hose. Hose must be free of kinks, seated flush to bottom of evaporator housing, and have drain valve at bottom of
hose. Valve must retain 1" of water in hose for proper function.

All Technical Service Bulletins for Housing Assembly HVAC: > < Heater Plenum Chamber <--> [Heater Core Case]|Service and Repair|Page 8631