A1
Components not located in passenger compartment |
Component group „1“ |
1 - | Receiver |
q | Integrated into condenser |
q | Exploded view → Chapter |
2 - | Condenser |
q | Only to be removed after draining refrigerant circuit → Air conditioner with refrigerant R134a |
q | Exploded view → Chapter |
3 - | Air conditioner compressor regulating valve -N280- |
q | Fitted in air conditioner compressor |
q | Checking cut-in signal → Chapter |
4 - | Air conditioner compressor |
q | Different versions → Electronic parts catalogue |
q | Removing and installing → Chapter |
q | Detaching and attaching refrigerant line at air conditioner compressor → Chapter |
q | Renewing pulley → Chapter |
5 - | Label |
q | Indicates type of refrigerant and specified capacity |
q | For refrigerant R134a capacity and notes on refrigerant, refer to → Air conditioner with refrigerant R134a |
6 - | Right water drain |
q | Checking → Chapter |
7 - | Left forced air extractor |
q | Checking → Chapter |
q | Removing and installing → Chapter |
8 - | Right forced air extractor |
q | Checking → Chapter |
q | Removing and installing → Chapter |
9 - | Heated rear window -Z1- |
q | Not part of air conditioner controls |
q | Checking actuation → Current flow diagrams, Electrical fault finding and Fitting locations and „Guided fault-finding“Onboard supply control unit -J519- → Vehicle diagnostic tester |
10 - | Left water drain |
q | Checking → Chapter |
11 - | Ambient temperature sensor -G17- |
q | The measured value of the ambient temperature sensor -G17- is evaluated by the control unit in dash panel insert -J285- and transmitted via the data bus to the operating unit, Climatronic control unit -J255- / air conditioning system control unit -J301-. For checking, „read measured values“ in the „Guided fault-finding“ function, dash panel, air conditioner → Vehicle diagnostic tester |
q | Removing and installing → Chapter |
Component group „2“ |
1 - | Expansion valve |
Note
After switching off the air conditioner compressor, a relatively long period may elapse before the pressure on the high-pressure end decreases (the expansion valve is cold and the pressure on the low-pressure end increases rapidly after switch-off, the expansion valve closes and the refrigerant can only flow slowly to the low-pressure end). |
q | Exploded view → Chapter |
2 - | Radiator fan -V7- |
q | The request for radiator fan cut-in is transmitted by the operating unit, Climatronic control unit -J255- / air conditioning system control unit -J301- via the data bus to the corresponding engine control unit. This engine control unit then actuates the radiator fan -V7- directly or by way of the radiator fan control unit → Rep. gr.19 |
q | To check actuation of the radiator fans by the operating unit, Climatronic control unit -J255- / air conditioning system control unit -J301-, „read measured values“ in the „Guided fault-finding“ function → Vehicle diagnostic tester |
q | The corresponding engine control unit switches the radiator fan -V7- (either directly or by way of the radiator fan control unit) to any desired output (depending on engine type) → Vehicle diagnostic tester, „Guided fault-finding“ function and → Current flow diagrams, Electrical fault finding and Fitting locations. |
q | Depending on the vehicle model, a radiator fan 2 -V177- may also be fitted → Rep. gr.19. |
3 - | Service connection on high-pressure end |
q | For measurement, drainage and filling of refrigerant circuit → Air conditioner with refrigerant R134a |
q | Cap with seal, always to be screwed on |
Caution
|
4 - | High-pressure sender -G65- |
q | Removing and installing → Chapter |
q | Checking → Chapter |
q | 8 Nm |
5 - | Service connection on low-pressure end |
q | For measurement and drainage of refrigerant circuit → Air conditioner with refrigerant R134a |
q | Cap with seal, always to be screwed on |
Caution
|
6 - | Fresh air intake grille |
q | Stops foreign matter (e.g. leaves) ingressing into the intake housing of the air conditioning unit |
q | Check for proper attachment |
q | Removing and installing → Chapter |
7 - | Condensation drain |
q | Checking → Chapter |
q | Removing and installing → Chapter |