A1
Exploded view - motor/pump unit |
t | There is no provision for repairing the motor/pump unit. |
t | If problems are reported, determine the cause by means of a pressure test and a leakage test. |
t | Always check the steering system for leaks if the hydraulic fluid level in the reservoir is low. |
t | In the event of any leaks near line connections, re-tighten connections and wipe dry. |
t | Do not re-use hydraulic fluid which has been drained off. |
t | Always renew seals. |
t | Quantity of fluid in system: approx. 0.8 ltr. |
1 - | Cap with dipstick |
q | Checking hydraulic fluid level → Chapter |
2 - | Seal |
3 - | Fluid reservoir |
q | Renewing → Chapter |
4 - | Clamp |
q | 3 Nm |
q | For correct version refer to → Electronic parts catalogue „ETKA“ |
5 - | Seal |
q | For correct version refer to → Electronic parts catalogue „ETKA“ |
q | Always renew if removed |
6 - | Motor/pump unit |
q | With power steering control unit -J500- |
q | No provision for repair |
q | Only the fluid reservoir → Item, clamp → Item and seal → Item can be renewed. |
q | Removing and installing → Chapter |
q | Checking delivery pressure → Chapter |
7 - | Mounting |
q | Tightening torque: 7 Nm |
q | Check for damage, such as cracks in rubber, separation of metal plate from rubber etc. and renew as required |
8 - | Nut |
q | 7 Nm |
q | When tightening, counterhold at mounting → Item |
9 - | Bolt |
q | 20 Nm +90° |
q | Always renew if removed |
10 - | Bracket |
q | For motor/pump unit |
q | Different versions available |
q | For correct version refer to → Electronic parts catalogue „ETKA“ |
11 - | Pressure line |
12 - | Union screw |
q | 30 Nm |
13 - | Seal |
q | Always renew if removed |
14 - | Spring-type clip |
15 - | Return line |