◆ The following table lists all faults that can be recognised by the transmit/receive control module for interior monitoring and printed out using V.A.G 1551. The faults are listed in order according to their 5-digit code numbers.
◆ Fault codes appear only on print-out.
◆ Before replacing a component shown as faulty, check wiring and connectors to component as well as earth connections according to current flow diagram.
◆ After carrying out repairs, activate and deactivate system once. Then interrogate fault memory again with fault reader V.A.G 1551 and erase memory.
◆ The fault memory records all static and sporadic faults. When a fault occurs it is immediately identified as a static fault. If fault does not occur again it is registered as a sporadic fault. "/SP" appears on the right of the display.
◆ All faults present are set to sporadic after activation and are only stored as being static if they are still present on completion of checking.
◆ Sporadic faults which no longer occur after 50 activation cycles are erased automatically.
Output on printer V.A.G 1551
Possible causes of fault
Fault remedy
01462
Ultrasonic sensor for anti-theft alarm -G209
Implausible signal
- Fault in wiring or connectors - Transmit/receive module for interior monitoring -G303 defective