Vehicle diagnostic, testing and information system -VAS 5051-, measurement mode: Multimeter, current measurement (10 A =) l
| Adapter -V.A.G 1598/12- connected |
|
Test step | Test box -V.A.G 1598 A- socket | Being tested: | | Specification | Remedies if the specification is not attained |
7.1 | 8 + 14 | Actuation of speed 1 for the radiator fan -V7- | –
| The fan does not start running until the test lead has been connected |
| t
| Greater than 0.1 A and less than 1.0 A |
| –
| Using the current flow diagram, locate and rectify a short circuit to earth in the wiring between the operating and display unit for air conditioner/Climatronic -E87- and the control unit for the radiator fans -J293- |
|
| | | | | –
| Using the current flow diagram, locate and rectify an open circuit in the wiring between the operating and display unit for air conditioner/Climatronic -E87- and the control unit for the radiator fans -J293- |
|
7.2 | 9 + 14 | Actuation of speed 2 for the radiator fan -V7- | –
| The fan does not start running until the test lead has been connected |
| t
| Greater than 0.1 A and less than 1.0 A |
| –
| Using the current flow diagram, locate and rectify a short circuit to earth in the wiring between the operating and display unit for air conditioner/Climatronic -E87- and the control unit for the radiator fans -J293- |
|
| | | | | –
| Using the current flow diagram, locate and rectify an open circuit in the wiring between the operating and display unit for air conditioner/Climatronic -E87- and the control unit for the radiator fans -J293- |
|