| Display zone | Meaning | Explanatory Notes |
| 1 | Actual feedback value for the potentiometer in the positioning motor for recirculated-air flap -G143- (in the positioning motor for recirculated-air flap -V113- | | l
| Display value greater than “5” and less than “250” |
| l
| Maximum permissible deviation: 3 units from the specified feedback value (in the range greater than 50 but less than 200) |
|
| 2 | Target feedback value for the potentiometer in the recirculated-air flap positioning motor -G143- (calculated by the operating and display unit for air conditioner/Climatronic -E87-) | | l
| Display range 5 ... 250 |
|
| 3 | Value for the potentiometer in the recirculated-air flap positioning motor -G143- ascertained during “basic setting” and saved in the operating and display unit for air conditioner/Climatronic -E87- with the positioning motor in the “very bottom” position (recirculated-air mode) | | l
| Display value greater than “5” and less than “50” |
|
| 4 | Value for the potentiometer in the recirculated-air flap positioning motor -G143- ascertained during “basic setting” and saved in the operating and display unit for air conditioner/Climatronic -E87- with the positioning motor in the “very top” position (air flow mode) | | l
| Display value greater than “200” and less than “250” |
|