audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Programming the creep point > < If during the basic setting the connection is interrupted/breaks off
If faults occur during basic setting
If faults occur during basic setting
If faults occur during basic setting, these are also shown on the display. The faults are not displayed consecutively, instead only the first fault to occur is displayed. At the end of the basic setting, an entry is also made in the fault memory.
   
Faults are displayed as follows:
Display zonesExplanations
1RTFM !Basic setting aborted.
2  
37Possible fault displays and their meaning:
t  7 - Potentiometer 2 for gear recognition -G240-
t  8 - Potentiometer 1 for gear recognition -G239-
t  9 - Reversing light switch -F4-
Remedy:
–  Check switches and wiring in the measured value blocks and according to current flow diagram
t  10 - Potentiometer values not stable during measurement
t  11 - Potentiometer values
Remedy
–  Check the corresponding potentiometers in measured value blocks 015 to 018 → Chapter
–  Interrogate fault memory and eliminate faults in line with fault tables → Chapter
–  Initiate basic setting again after repair → Chapter
t  12 - Gear actuator is not adjusted correctly or the measured values are outside the tolerances
Remedy
–  Check potentiometer, valves and selector finger at the ball heads for correct assembly and seating
–  Initiate basic setting again after adjusting the gear actuator → Chapter
Further notes → Chapter „Basic setting cannot be performed“
4  

   

Programming the creep point > < If during the basic setting the connection is interrupted/breaks off