Display zones | Explanations |
1 | RTFM ! | Basic setting aborted. |
2 | | |
3 | 7 | Possible fault displays and their meaning: |
t
| 7 - Potentiometer 2 for gear recognition -G240- |
t
| 8 - Potentiometer 1 for gear recognition -G239- |
t
| 9 - Reversing light switch -F4- | Remedy:–
| Check switches and wiring in the measured value blocks and according to current flow diagram |
|
t
| 10 - Potentiometer values not stable during measurement |
t
| 11 - Potentiometer values | Remedy –
| Check the corresponding potentiometers in measured value blocks 015 to 018 → Chapter |
–
| Interrogate fault memory and eliminate faults in line with fault tables → Chapter |
–
| Initiate basic setting again after repair → Chapter |
|
t
| 12 - Gear actuator is not adjusted correctly or the measured values are outside the tolerances | Remedy –
| Check potentiometer, valves and selector finger at the ball heads for correct assembly and seating |
–
| Initiate basic setting again after adjusting the gear actuator → Chapter | Further notes → Chapter „Basic setting cannot be performed“ |
4 | | |