Note! t
| Repairs must not be performed on the motor/pump unit |
t
| If problems are reported, trace the fault by means of a function test, pressure test, leak test and self-diagnosis. |
t
| If a fault is found, the motor/pump unit must be renewed. |
t
| Small quantities of hydraulic fluid will remain in the motor/pump unit as well as in the return line and expansion hose after extraction. |
t
| Do not re-use hydraulic fluid which has been drained off. |
t
| The expansion hose and return line must not be clamped with hose clamps, e.g. -3094- or other tools. Clamping can cause damage to the expansion hose and return line. |
t
| To avoid damage, a bending radius of less than 100 mm is not permissible when bending or suspending the expansion hose and return line. |
t
| For tightening torques, refer to → Chapter onwards. |
|
|
|