audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Parking aid (parking system) self-diagnosis > < Adaption following replacement of dash panel insert and engine control unit
Electrical system, Self-diagnosis
Immobilizer self-diagnosis - immobilizer III
Login procedure

Notes:

  • ◆ The PIN number must be established on the basis of the 14-position identification number of the immobilizer/engine control unit by way of direct system interrogation (as for direct interrogation of radio code). It is also possible to find out the PIN number from the appropriate Regional Sales Centre or importer.
  • ◆ Three incorrect PIN number entries disable the immobilizer/engine control unit.
  • ◆ A futher attempt can only be made after 10 minutes (ignition is to be left permanently switched on during this period and exit from self-diagnosis mode effected by way of function 06 "End output"). Time is doubled up to max. 255 minutes after every 3 further incorrect attempts.

Dash panel insert login procedure

 
→ Indicated on display:
Rapid data transfer    HELP
Select function XX
  • ‒ Press key 1 twice to select "Login procedure" function.
 
→ Indicated on display:
Rapid data transfer    Q
11 - Login procedure
  • ‒ Confirm entry with Q key.
 
→ Indicated on display:
Login procedure
Enter code number    XXXXX
  • ‒ Enter PIN number with a 0 before the 4-digit number (e.g. 01915).
  • ‒ Confirm entry with Q key.

Note:

Once login procedure has been successfully completed, lamp lights continuously and immobilizer is released:

  • ◆ As long as engine is running and ignition key remains in lock
  • ◆ For 45 min. if ignition key remains in lock (engine not running)
  • ◆ For 5 min. if ignition key is removed
 
→ Indicated on display:
Rapid data transfer    HELP
Select function XX

Attention:

 
→ If this display appears during login procedure, PIN number has been entered incorrectly (e.g. wrong PIN number).
Function unknown or cannot     ⇒
be implemented at present

Engine control unit login procedure

 
→ Indicated on display:
Rapid data transfer    HELP
Select function XX
  • ‒ Press key 1 twice to select "Login procedure" function.
 
→ Indicated on display:
Rapid data transfer    Q
11 - Login procedure
  • ‒ Confirm entry with Q key.
 
→ Indicated on display:
Login procedure
Enter code number    XXXXX
  • ‒ Enter PIN number with a 0 before the 4-digit number (e.g. 01915).
  • ‒ Confirm entry with Q key.
 
→ Indicated on display:
Rapid data transfer    HELP
Select function XX

Engine control unit has now been released.

Attention:

 
→ If this display appears during login procedure, PIN number has been entered incorrectly (e.g. wrong PIN number).
Function unknown or cannot     ⇒
be implemented at present

Parking aid (parking system) self-diagnosis > < Adaption following replacement of dash panel insert and engine control unit