Refrigerant: Capacity Specifications

Refrigerant R134a Capacities 

NOTE: 

-

When charging the high-pressure side of refrigerant circuits, always fill to the upper tolerance limit (some liquid refrigerant remains in the
charging hoses).

-

For compressor assignment ("Zexel", "Sanden" or "Denso/Nippondenso"), refer to Parts List and Heating, air conditioning or Air conditioning.

NOTE:  Refrigerant circuits converted from R12 to R134a are to be filled with the quantity indicated in the "Air conditioner with refrigerant R12".

Capacities for Audi A3 (8L_) 1997 to 2004 and Audi TT (8N_) 1999--> 

Features of the refrigerant system: 

-

Expansion valve

-

Receiver

-

Compressor from manufacturers "Sanden" or "Zexel" Heating, air conditioning and Parts Catalog

Capacities Audi A3 (8L_) 1997 up to 2004 

NOTE: 

-

Exclusive use was made at the start of production of "Sanden" compressors. As of model year 1999, use was also made of "Zexel" compressors
Heating, air conditioning and Parts Catalog.

-

If no condenser with a flat pipe width of 20 mm is available for Audi A3 as a replacement part, an a condenser with a flat pipe width of 16 mm is
installed, only 650 ± 20 g of refrigerant instead of 750 + 50 g may be filled in. In addition, capacity specification must be changed accordingly on
sticker

Determining dimensions of flat pipes from condenser 

-

Flat pipes of condenser -A-

-

Width of flat pipes -B-

Sticker for capacity of refrigerant R134a 

Refrigerant|Capacity Specifications|Page 4056 > < All Technical Service Bulletins for Refrigerant:|871010|Page 4053