Note –
| Place used oil collection and extraction unit -V.A.G 1782- below gearbox. |
–
| Remove countersunk bolt securing flange shaft (left-side). To do so, screw two bolts into flange and counterhold flange shaft with suitable lever. |
–
| Pull out flange shaft and spring. |
Installation is carried out in reverse sequence; note the following: |
Note Renew countersunk bolt securing flange shaft. |
–
| Push in flange shaft against spring pressure and secure using new bolt. |
|
|
|