Removing and installing coolant pump > < Removing and installing continued coolant circulation pumpV51
Removing and installing solenoid valve for coolant circuitN492
Removing and installing solenoid valve for coolant circuit -N492-
Special tools and workshop equipment required
   
t  Hose clamps for hoses up to 25 mm -3094-
  W00-0079
t  Hose clip pliers -VAS 6362-
  W00-10427
Removing
–  Pull cover -1- off air duct (release clip on side).
–  Unclip air duct -2-.
  Note
  A10-1878
Place a cloth underneath to catch escaping coolant.
–  Unplug electrical connector -1-.
–  Remove bolts -arrows- and detach solenoid valve for coolant circuit -N492-.
–  Clamp off coolant hoses -2- with hose clamps up to 25 mm -3094- and detach.
Installing
Installation is carried out in the reverse order; note the following:
l  Tightening torque → Chapter „Coolant pump and thermostat with housing - exploded view“
  Note
Secure all hose connections with the correct type of hose clips (same as original equipment) → Electronic parts catalogue.
–  Install front air duct → Rep. gr.24.
–  Check coolant level → Anchor.
  A19-10963