| l
| Vacuum hoses and hose connections do not leak. |
| l
| Vacuum hoses are not clogged. |
| –
| Disconnect hose for secondary air system -arrow- and connect test hose to hose leading to combination valve for secondary air system. |
| –
| Blow lightly into test hose with your mouth (do not use compressed air). |
| l
| The combination valve for secondary air system should be closed; it should not be possible to blow through the hose. |
| –
| Blow into test hose with your mouth using more pressure (do not use compressed air). |
| l
| The combination valve for secondary air system should open; it should now be possible to blow through the hose. |
| –
| Renew combination valve for secondary air if you cannot determine the switching point → Chapter. |
|
|
|