| Carefully clean contact surface -2- for O-ring. |
–
| Take care not to twist O-ring -1- when fitting it. |
Caution Risk of return hoses coming loose. |
Always renew retaining clip if removed. |
|
–
| Coat new retaining clips for return lines with grease. |
–
| Press return lines onto side of injector and press on retaining clip using long-nose pliers. |
–
| Check that return lines are properly secured by pulling them. |
–
| Bleed fuel system and then check it for leaks → Chapter. |
|
|
|