Checking ATF level
- Make
- Audi
- Model
- A3 Mk3
- Year
- 2012–2020
- Section
- ATF › Checking ATF level
Checking ATF level
Please note:
- If ATF needs to be filled up, only use ATF available as a replacement part Electronic parts catalogue.
- For some fluid containers, an additional adapter VAS 6262/6 must be used.
- It may be necessary to shorten breather pipe of adapter for oil filling VAS 6262 AAnchor.


To ensure that breather pipe of adapter for oil filling VAS 6262 A does not make contact with bottom of oil container, breather pipe must be shortened to dimension (a).
Dimension (a) = 210 mmNote
- Dimension (a) is measured from stem (green area in magnified view) of adapter for oil filling VAS 6262 A.
Mark dimension (a) on breather pipe and shorten pipe with e.g. pipe cutter VAS 6056/2.


- Vehicle must be level with all lifting platform supports at same height
- Noise insulation removed
- Vehicle diagnostic tester connected
- The fluid temperature must not be higher than 45 °C at the beginning of the test.
- Test temperature: 35 ... 45 °C
Connect Vehicle diagnostic tester.
Select Diagnosis mode and start diagnosis.
Select Test plan tab.
Select Own test and select the following in succession from tree:
- Drive system
- Automatic gearbox 09G
- 01 - Self-diagnosis-compatible systems
- 02 - Gearbox electronics J217
- 02 - Gearbox electronics, functions
- 02 - Check ATF level
Note
- If the temperature of the fluid is higher than 45 °C, allow the gearbox to cool down before proceeding.
Engine running at idling speed and selector lever in “P”.
Place drip tray for workshop hoist or used oil collection and extraction unit V.A.G 1782 underneath gearbox in area of ATF inspection plug.
Unscrew ATF inspection plug (arrow).

Renew seal (arrow) for plug.

Note
- Even when the fluid level is too low a small amount of fluid will first drain out of the overflow pipe, as it fills up during operation.
The ATF present in the overflow pipe runs out.

Allow excess fluid to drain off.
As soon as fluid has drained off (when it begins to drip), fit plug with new seal.
If no fluid drains, fluid must be added.
With engine running, screw adapter for oil filling VAS 6262/2 into inspection hole (hand-tight).

Shake oil containers before opening.
Warning The ATF charging device must be clean and the ATF must not be mixed with other types of ATF!
Select correct type Electronic parts catalogue.
Screw adapter for oil filling VAS 6262 A onto container, observing notes Anchor.
Fill with 1 ltr. of ATF.
Pull adapter for oil filling VAS 6262 off at quick-release coupling and check:
ATF does not need to be filled up.
Allow ATF to drain off until it drips.
Tighten ATF inspection plug with new seal. The ATF level check is now completed.
Another litre must be added Anchor.
Warning The fluid level must not be too low or too high, otherwise this would impair the function of the gearbox.
- Chapter“Exploded view - valve body”
Parts & tools for this job For 2012 Audi A3
- PARTTransmission filter kitSearch: Audi A3 2012 transmission filter kit
- FLUIDAutomatic transmission fluidSearch: Audi automatic transmission fluid
- TOOLFluid transfer pumpSearch: fluid transfer pump
As an Amazon Associate we earn from qualifying purchases.