Calibrating reversing camera R189
Ensure requirements are met Anchor.
Connect Vehicle diagnostic tester.
Fit wheel centre mounting VAS 6350/1:
Check the bolt hole circle pattern on the wheels.
Prepare wheel centre mountings VAS 6350/1 as required.
To do so, secure three wheel bolt adapters to each wheel centre mounting VAS 6350/1 to match the hole circle.
Position paddles on both wheel centre mountings VAS 6350/1 and secure each paddle with clamping bolt.
Fit wheel centre mountings VAS 6350/1 onto wheel bolts on rear wheels.
The wheel centre mountings VAS 6350/1 are kept in position by the O-rings in the adapters.

Note
- When fitting the wheel centre mountings VAS 6350/1 onto the wheels, make sure that they are not mounted on any “anti-theft” wheel bolts that might be installed.
Use clamping bolts to adjust paddles so that they are free to move just slightly above the ground. Make sure the paddles can move freely.
Set up and align calibration unit VAS 6350Chapter.
Measuring gap:
Switch on spacing laser VAS 6350/2.
The following display will appear:
The display will show how the spacing laser VAS 6350/2 should be positioned. Press the appropriate key.

Hold spacing laser VAS 6350/2(2) flush with bracket on one side of the calibration unit as shown in illustration. Spacing laser VAS 6350/2(2) must make firm contact with bracket.

Briefly press the measurement button.
The laser will switch on.
Laser beam from spacing laser VAS 6350/2(2) must hit lower, larger part of paddle (1).
If this is not the case, position of paddles must be corrected accordingly using clamping bolts on wheel centre mounting VAS 6350/1.
Hold spacing laser VAS 6350/2 in locating bracket on calibration unit VAS 6350 with one hand while laser beam is visible on paddle.
Now press measurement button briefly to measure distance.
Note down the measured value.
Perform same measuring procedure for rear wheel on other side of calibration unit VAS 6350.
Measured distance value must be identical on both sides.
If values are not identical:
Adjust calibration unit VAS 6350 until values on both sides are identical.
When adjusting, make sure that linear laser VAS 6350/3 hits centre of Audi rings and spirit level display also remains central. Correct if necessary.
Measuring dimension (H):
Measure height of calibration unit VAS 6350: dimension (H) (top edge of platform - floor).

Ensure that spacing laser VAS 6350/2 is correctly adjusted (position at front edge).
The display will show how the spacing laser VAS 6350/2 should be positioned. Press the appropriate key.

Now enter measured distance value and height in millimetres in Vehicle diagnostic tester.
Vehicle diagnostic tester is connected.
Select Diagnosis mode and start diagnosis.
Select Test plan tab.
Select Own test then the following options one after the other:
- Body
- Electrical system
- 01 - Self-diagnosis compatible systems
- 6C - Rear-view camera system - J772
- 6C - Reversing camera system control unit, functions
- 6C - Calibrate
Further instructions are given by Vehicle diagnostic tester during calibration procedure.
Warning Make sure no light is reflected on calibration platform.
Reflected light impairs the view of the reversing camera R189 and therefore it may be impossible to perform calibration.