Exploded view - heater unit
Note
- The heater unit is available in different versions and from different manufacturers. The individual components of the various heaters are similar but not identical; the combination of components by different manufacturers is therefore not permissible Electronic parts catalogue.
- The following illustrations show a Valeo heater; distinguishing features compared to heaters from other manufacturers → Chapter.

- Operating lever
For actuating defroster flap and air distribution flap - Air distribution flap control motor V428
With potentiometer for air distribution flap control motor G645
Checking Vehicle diagnostic tester (“Guided Fault Finding”) and Current flow diagrams, Electrical fault finding and Fitting locations
Removing and installing → Chapter - Bolt
2x
Tightening torque → Chapter - Bolt
3x
Tightening torque → Chapter - Bolt
2x
Tightening torque → Chapter - Temperature flap control motor V68
With potentiometer for temperature flap control motor G92
Checking Vehicle diagnostic tester (“Guided Fault Finding”) and Current flow diagrams, Electrical fault finding and Fitting locations
Removing and installing → Chapter - Operating lever
For activating warm air flap - Heater
Different versions → Chapter
It is not permissible to install the wrong components together Chapter“Identification of heater and air conditioning unit”
The following illustrations show a Valeo heater.
The design is largely identical to that of the heater/air conditioning unit.
Not incorporated: expansion valve, condensation drain, evaporator etc.
A honeycomb element is installed instead of the evaporator.
There is no opening for the expansion valve in the seal for the plenum chamber back wall, or it is closed off by a foam pad.
Exploded view → Chapter - Actuator for defroster and air distribution flap
Removing and installing → Chapter

- Bolt
Tightening torque → Chapter - Coolant pipe for heat exchanger
Different versions Electronic parts catalogue
Coolant supply from engine
Removing and installing → Chapter - Clip
Can also be replaced by a clamp in the course of service work - Coolant pipe for heat exchanger
Different versions Electronic parts catalogue
Coolant return to engine
Removing and installing → Chapter - O-ring
Different versions Electronic parts catalogue
Renew - Cover
For heat exchanger - Bolt
Tightening torque → Chapter - Foam spacer
For seal/insulation
Vehicles without air conditioner: no opening for expansion valve Electronic parts catalogue
Note installation position - Bracket
For coolant pipes - Foam
For insulation
Note installation position - Heater
The opening for the supplementary heater is sealed on vehicles without auxiliary air heater element Z35
Removing and installing → Chapter
Dismantling and assembling → Chapter - Heat exchanger
Different versions Electronic parts catalogue
Removing and installing → Chapter - Auxiliary air heater element Z35
Checking activation → Chapter
Removing and installing → Chapter - Bolt
2x
Tightening torque → Chapter - Electrical wire
For auxiliary air heater element Z35
Detaching and attaching Chapter“Removing and installing auxiliary air heater element Z35” - Earth wire
For supplementary heater
Tightening torque → Chapter - Bolt
3x
Tightening torque → Chapter - Clamp
- O-ring
Different versions Electronic parts catalogue
Renewing Chapter“Removing and installing heat exchanger”

- Bolt/clip
2x
Tightening torque for bolt ChapterNoteDifferent versions; renew clip version if necessary Electronic parts catalogue.Use e.g. pliers or a screwdriver to prise out version with clip. - Cover
- Housing (top section)
- Bolt
2x
Tightening torque → Chapter - Air intake duct
Do not dismantle
With fresh air and air recirculation flap
Different versions Electronic parts catalogue
Removing and installing → Chapter - Not installedOnly installed on vehicles with automatic air conditioner Chapter“Exploded view - attachments for heater and air conditioning unit and air intake box”
- Not installedOnly installed on vehicles with automatic air conditioner Chapter“Exploded view - attachments for heater and air conditioning unit and air intake box”
- Air recirculation flap control motor V113
Without potentiometer with limit switches at end stops Current flow diagrams, Electrical fault finding and Fitting locations
Checking Vehicle diagnostic tester (“Guided Fault Finding”) and Current flow diagrams, Electrical fault finding and Fitting locations
Removing and installing → Chapter - Bolt
2x
Tightening torque → Chapter - Dust and pollen filter
Different versions Electronic parts catalogueNoteNot fitted with an activated charcoal filter insert at the factory on vehicles without air conditioner and vehicles with manually controlled air conditioner → Chapter
Replacement interval Maintenance tables
Removing and installing → Chapter - Cover
For dust and pollen filter - Fresh air blower V2
Checking Vehicle diagnostic tester (“Guided Fault Finding”) and Current flow diagrams, Electrical fault finding and Fitting locations
Removing and installing → Chapter - Fresh air blower control unit J126
Checking Vehicle diagnostic tester (“Guided Fault Finding”) and Current flow diagrams, Electrical fault finding and Fitting locations
Removing and installing → Chapter - Bolt
2x
Tightening torque → Chapter
Parts & tools for this job For 2012 Audi A3
- TOOLA/C manifold gauge setSearch: AC manifold gauge set
- TOOLUV leak detection kitSearch: AC UV leak detection kit
- PARTCabin filterSearch: Audi A3 2012 cabin filter
As an Amazon Associate we earn from qualifying purchases.