Rules for cleanliness (Heating, air conditioning)
- Make
- Audi
- Model
- A3 Mk3
- Year
- 2012–2020
- Section
- Repair instructions › Rules for cleanliness
Heating, air conditioningRules for cleanliness
Rules for cleanliness
- Immediately seal off open lines and connections with clean plugs, e.g. from engine bung set VAS 6122.
- Place parts that have been removed on a clean surface and cover them over (do not use fluffy cloths).
- Carefully cover or seal open components if repairs cannot be carried out immediately.
- Only install clean components: Replacement parts should only be unpacked immediately prior to installation. Do not use parts that have been stored without their packaging (e.g. in toolboxes etc.).
- Do not work with compressed air when the system is open.
- Protect unplugged connectors against dirt and moisture and always make sure they are dry before plugging them in again.
Parts & tools for this job For 2012 Audi A3
- TOOLA/C manifold gauge setSearch: AC manifold gauge set
- TOOLUV leak detection kitSearch: AC UV leak detection kit
- PARTCabin filterSearch: Audi A3 2012 cabin filter