Workshop Manuals Factory service & repair Audi
01 4-cylinder TDI engine, 1.6 ltr.; 2.0 ltr. 4-valve common rail (EA 288 Gen. I)02 Fuel supply system, diesel engines03 4-cylinder direct injection engine (1.2, 1.4 ltr. 4-valve TFSI EA 211)04 Fuel supply system, petrol engines05 4-cylinder direct injection engine (1.8, 2.0 ltr. 4-valve TFSI - generation III)06 Fuel supply system - g-tron07 4-cylinder direct injection engine (1.4 ltr. 4-valve TFSI) - g-tron08 5-cylinder direct injection engine (2.5 ltr. 4-valve TFSI)09 Technical data for engines10 Servicing 7-speed dual clutch gearbox 0AM/0CW11 7-speed dual clutch gearbox 0CW (S tronic)12 Rear final drive 0CQ, 0CR13 5-speed manual gearbox 0A414 6-speed manual gearbox 0AJ15 6-speed manual gearbox 02Q, 0FB16 6-speed manual gearbox 02S17 6-speed dual clutch gearbox 0D918 5-speed manual gearbox 0AH19 6-speed dual clutch gearbox 0DD20 6-speed automatic gearbox 09G21 Servicing 6-speed manual gearbox 02Q, 0BB, 0FB22 7-speed dual clutch gearbox 0DL23 Running gear: Trailer Operation Guide24 Running gear, axles, steering25 Brake system26 Running gear: Wheel/Tyre Guide27 Heating and air conditioning: Auxiliary/supplementary heater28 Heating, air conditioning29 Electrical system30 Electrical: Communication31 Electrical: Basic information on high-voltage vehicles32 General body repairs, interior33 General body repairs, exterior
Audi A3 Mk3 (2012-2020)28 · Heating, air conditioning
28 · Heating & A/C

Safety precautions when handling refrigerants

Make
Audi
Model
A3 Mk3
Year
2012–2020
Section
Safety precautions › Safety precautions when handling refrigerants
Heating, air conditioningSafety precautions when handling refrigerants

Safety precautions when handling refrigerants

Air conditioner with refrigerant R134a

The components and piping system of the air conditioner are filled with the following refrigerant:

1.1.1 2-tetrafluoroethane (CF3-CH2F or CH2F-CF3)

This refrigerant is currently known in Germany by the trade names R134a, H-FKW 134a, SUVA 134a and KLEA 134a (other trade names may be used in other countries).

In Germany, observe the following safety measures for this refrigerant (additional regulations may apply in other countries).

Warning Refrigerant is a potential health hazard!

  • Before performing repair work on an open refrigerant circuit, discharge the refrigerant circuit Air conditioner with refrigerant R134aRep. gr.87Refrigerant circuit (Air conditioner with refrigerant R134a; Refrigerant circuit; Working with the air conditioner service station).
  • Always perform work on the refrigerant circuit in well ventilated areas. Make sure that there are no inspection pits, open shafts or cellar entrances within a radius of 5 metres.

Warning Danger of asphyxiation if refrigerant escapes (due to mixture of air and refrigerant).

  • Switch on the exhaust gas extraction system.
  • Escaping refrigerant is colourless, odourless and heavier than air (it displaces oxygen). Should refrigerant gas escape, this can result in an imperceptible danger of asphyxiation in poorly ventilated areas and inspection pits.
Risk of dry coughing and nausea caused by toxic chemical decomposition products of refrigerant gas.
  • Smoking, welding, soldering and brazing are not permitted in areas exposed to refrigerant. The high temperature of a naked flame or hot objects causes decomposition of refrigerant gas. The resultant decomposition products are toxic.
Risk of eye injuries!
  • Keep an eye-bath to hand.
  • Should liquid refrigerant come into contact with your eyes, rinse them thoroughly with water for about 15 minutes.
  • Then apply eye drops and consult a doctor immediately, even if you do not experience any pain in the eyes.
  • Always inform the doctor of the type of refrigerant involved.
Intensive exposure to refrigerant would cause frostbite on unprotected parts of the body. All contact with liquid refrigerant or refrigerant vapours should be avoided.
  • Wear rubber gloves to protect your hands.
  • Wear safety goggles to protect your eyes.
  • Should liquid refrigerant come into contact with other parts of the body, rinse these thoroughly with cold water for about 15 minutes.

Warning Danger from escaping pressurised refrigerant.
Frostbite on skin and other parts of the body.
Extract the refrigerant and then immediately open up the refrigerant circuit.Extract the refrigerant again if more than 10 minutes have passed since the initial extraction and the refrigerant circuit has not been opened up. Renewed evaporation leads to the build-up of pressure in the refrigerant circuit.