Display zone | Significance | Explanatory notes |
1 | Actual feedback value of central flap control motor potentiometer -G112- (in central flap control motor -V70-) | l
| Display value greater than “9” and less than “251” |
l
| Maximum permissible deviation “3” units from specified feedback value (only in range greater than “70” but less than “190”) |
|
2 | Specified feedback value for central flap control motor potentiometer -G112- (calculated by operating and display unit, Climatronic control unit -J255-) | l
| Display range “10 ... 245” |
|
3 | Value determined during “Basic setting” and stored in the operating and display unit, Climatronic control unit -J255- for the central flap control motor potentiometer -G112- with control motor set to “Lower stop” (central and footwell flap closed, air flow is routed to defroster flap) | l
| Display value greater than “9” and less than “71” |
|
4 | Value determined during “Basic setting” and stored in the operating and display unit, Climatronic control unit -J255- for the central flap control motor potentiometer -G112- with control motor set to “Upper stop” (central flap open, footwell flap closed, air flow is routed to dash panel vents) | l
| Display value greater than “189” and less than “246” |
|