audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Display group "007” > < Display group "005”
Display group “006”
Display group “006”
Central flap control motor -V70-
   
Display zoneSignificanceExplanatory notes
1Actual feedback value of central flap control motor potentiometer -G112- (in central flap control motor -V70-)
l  Display value greater than “9” and less than “251”
l  Maximum permissible deviation “3” units from specified feedback value (only in range greater than “70” but less than “190”)
2Specified feedback value for central flap control motor potentiometer -G112- (calculated by operating and display unit, Climatronic control unit -J255-)
l  Display range “10 ... 245”
3Value determined during “Basic setting” and stored in the operating and display unit, Climatronic control unit -J255- for the central flap control motor potentiometer -G112- with control motor set to “Lower stop” (central and footwell flap closed, air flow is routed to defroster flap)
l  Display value greater than “9” and less than “71”
4Value determined during “Basic setting” and stored in the operating and display unit, Climatronic control unit -J255- for the central flap control motor potentiometer -G112- with control motor set to “Upper stop” (central flap open, footwell flap closed, air flow is routed to dash panel vents)
l  Display value greater than “189” and less than “246”

t  The following air conditioner operating statuses (and all intermediate settings) can be selected by way of the levers attached to the flaps depending on the position of the control motor:
–  Footwell and central flap closed = Defrost mode (air to windscreen)
–  Footwell flap open and central flap closed = Air to footwell (feedback value in display zones “1” and “2” between “110” and “150”).
–  Footwell flap closed and central flap open = Air from dash panel vents
  Note
The notes on display group “003” also apply to this display group and should be heeded if necessary → Anchor.
   

Display group "007” > < Display group "005”