| Pull burner element -A- out of auxiliary heater housing -B- (e.g. by way of mount for flame monitor in burner element housing). |
Note t
| Do not pull on impeller -C- of combustion air blower to remove burner element. |
t
| The combustion air blower -V6- runs at a maximum speed of approx. 8000 rpm and is thus balanced at the factory together with the impeller -C-. Care should therefore be taken on removal and installation not to squash or twist the impeller on the shaft of the combustion air blower -V6-. |
–
| Assemble in reverse order, paying attention to the following |
Note t
| Clean auxiliary heater combustion chamber and burner element prior to assembly. |
t
| In the case of a horizontally installed auxiliary heater, seal off burner element from housing in lower area → Chapter. |
|
|
|