Code | Significance of display in adaption channel "18" |
| | | | | "Auxiliary heating/ventilation" function |
| | | | 0 | No auxiliary heater fitted –
| No “auxiliary heating/ventilation” display in driver information system |
|
| | | | 1 | Auxiliary heating/ventilation fitted –
| Following engine operation, ON signal for auxiliary heating/ventilation remains active until set operating time has elapsed (factory setting) |
–
| After engine operation, auxiliary heating/ventilation can however be deactivated by the auxiliary heater control unit -J364- (even if ON signal is still being transmitted by control unit in dash panel insert -J285-) → Chapter |
|
| | | | 2 | Auxiliary heating/ventilation fitted –
| Following engine operation, ON signal for auxiliary heating/ventilation is deactivated automatically on switching off ignition (customer-specific setting, e.g. for driving short distances) |
|
| | | | | “Engine pre-heating” function in auxiliary heating mode |
| | | 0 | | “Inclu. engine” does not appear on driver information system display –
| Setting for vehicles with no heater coolant shut-off valve -N279- or for vehicles on which the heater coolant shut-off valve -N279- is not actuated by the auxiliary heater control unit -J364- (the coolant always flows via the engine in auxiliary heating mode) → Chapter |
|
| | | 1 | | “Inclu. engine” appears on driver information system display –
| Setting for vehicles with heater coolant shut-off valve -N279- (the heater coolant shut-off valve -N279- is actuated by the auxiliary heater control unit -J364-) → Chapter |
–
| If there is no tick against “Inclu. engine” in the driver information system display, the direction of coolant flow in auxiliary heating mode is governed by the coolant temperature in the auxiliary heater → Chapter. |
–
| If there is a tick against “Inclu. engine” in the driver information system display, the coolant flows (fully or to a certain extent) back to the auxiliary heater via the engine in auxiliary heating mode → Chapter |
|
| | | | | Additional functions |
0 | 0 | 0 | | | These zones are not used at present |