A = ON signal for auxiliary heater (supplementary heater) |
–
| The auxiliary heater control unit -J364- receives the request for activation as auxiliary heater (or supplementary heater) via the convenience data bus. |
a = Component check (approx. 2 seconds) |
–
| The auxiliary heater control unit -J364- checks the connected components |
b = Pre-heating time (approx. 6 seconds) |
c = Pre-heating and ventilation (approx. 7 seconds) |
D = Start of fuel delivery |
d = Start and flame formation (max. 90 seconds) |
–
| If no flame is detected, the auxiliary heater control unit -J364- terminates the starting procedure. On completion of the run-on time stored in the auxiliary heater control unit -J364-, the auxiliary heater control unit -J364- attempts a second start. If there is again no flame, the auxiliary heater control unit -J364- switches to fault status. |
e = Safety margin (approx. 6 seconds) |
–
| For flame stabilisation |
F = Start of full load operation |
–
| Full load operation (duration temperature-dependent) |
f 1 = The coolant temperature in the auxiliary heater reaches 30 °C (up to 45 °C depending on the version of the auxiliary heater control unit -J364-) and, in auxiliary heating mode, the operating and display unit, Climatronic control unit -J255- of the air conditioner/heater is requested by way of the convenience data bus system to switch on the fresh air blower -V2-. |
–
| At the start of full load operation, the heater coolant shut-off valve -N279- is actuated and, given a low coolant temperature, the coolant circuit is switched to the small circuit. |
f 2 = The coolant temperature in the auxiliary heater reaches 71 °C, the auxiliary heater control unit -J364- alters actuation of the heater coolant shut-off valve -N279- → Chapter |
|
|
|