Display group number | Display zone | Designation |
082 | 1 | Flash tool number of data level in auxiliary heater control unit -J364- |
| 2 | Date on which last flash was performed for auxiliary heater control unit -J364- (flash = input of new data) |
| 3 | Hardware (electronics) level of auxiliary heater control unit -J364- |
| 4 | Software level (electronics data level) of auxiliary heater control unit -J364- |
090 | 1 and 2 | Status of test performed on auxiliary heater manufacture for auxiliary heater control unit -J364-t
| Display = ARDIC TEST: Y |
–
| If “ARDIC TEST: N” is displayed, the auxiliary heater control unit -J364- does not activate the auxiliary heater (not all scheduled tests were performed on manufacture of auxiliary heater control unit -J364-). |
|
| 3 and 4 | Status of test performed at factory for auxiliary heater control unit -J364-t
| Display = BERIFORS TEST: Y |
–
| If “BERIFORS TEST: N” is displayed, the auxiliary heater control unit -J364- does not activate the auxiliary heater (not all scheduled tests were performed on manufacture of auxiliary heater control unit -J364-). |
|