| Unscrew the two bolts and remove exhaust gas pressure sensor 1 -G450-. |
–
| When installing, note the following: |
t
| Tightening torque for exhaust gas pressure sensor 1 -G450-: 3.5 Nm |
Note t
| Before installing, blow out hoses for exhaust gas pressure sensor 1 -G450- towards particulate filter with compressed air (hoses can become obstructed or may ice up due to condensation). |
t
| Make sure that hoses are securely fitted and seal properly. |
t
| If pressure connections are detached from particulate filter, tighten to 25 Nm. |
Adaption must be performed after renewing exhaust gas pressure sensor 1 -G450- and/or particulate filter. (The procedure is described under Guided Functions.) |
Select correct vehicle identification in Guided Fault Finding. |
–
| Press „Function/component selection“. |
–
| „01 - Self-diagnosis compatible systems“ |
–
| „01 - Engine electronics“ |
–
| Select „01 - Functions“. |
–
| „01 - J623 Adapt particulate filter learned values“ |
|
|
|