Basic setting
Basic setting
With engine stopped and ignition switched on, the following operation can be carried out with the "Function 04" basic setting:
-
◆ Adaption of the throttle valve control part to the engine control unit =>Display group 60
()
-
◆ Vehicles with automatic gearbox:Learning kickdown function of accelerator position sender to engine control unit =>Display group 63 ()
With the engine running, the following operations can be performed with the basic setting function:
-
◆ Learning process for lambda control
=> each display group
-
◆ Fault finding by selective activation and deactivation of the lambda control => display group 99 (please note relevant instructions on page 24-85).
Test conditions for operations with engine running
-
● No fault stored in fault memory
-
● Coolant temperature at least 80 °C (display group 4, display zone 3).
-
● Electrical consumers switched off (radiator fan must not run during the check)
-
● Air conditioner switched off
-
‒ Connect the vehicle diagnostic, testing and information system VAS 5051 or fault reader V.A.G 1551 and select the engine electronics control unit with "address word" 01 .
For this purpose, the engine must be running at idle speed.
-
‒ Interrogating and erasing fault memory.
=> Page 01-14. No faults must be stored (if necessary, rectify fault, erase fault memory, switch off and re-start engine, perform test drive and interrogate the fault memory again as a check.
-
‒ Leave engine idling.
|