audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Encoding operating and display unit for air conditioner/Climatronic -E87 (heating) > < Basic setting
Heating
Erasing fault memory, end of output
Erasing fault memory, end of output
  • ‒ With ignition off, connect up vehicle diagnostic, testing and information system VAS 5051 with diagnostic cable VAS 5051/1 to 16-pin diagnostic socket in vehicle and select electronic air conditioner/heater with "address word" 08 .

Erasing fault memory

Requirements:

  • ● Fault memory interrogated => Page 01-18 and all displayed faults eliminated
 
A87-0314

→ Indicated on display of V.A.S 5051:

  • ‒ Select function "05 - Erasing fault memory".
 
A87-0320

→ Indicated on display of V.A.S 5051:

  • ◆ There is no display in zone -1-.
  • ◆ A box with a note indicating that touching the "OK" key will erase data (fault memory) and requiring confirmation that function is to be executed appears in display zone -2-.

Notes:

  • ◆ If "Fault memory not yet interrogated" appears in display zone -1-:
  • ‒ Interrogate fault memory.
  • ‒ Eliminate any faults.
  • ◆ Fault memory is not erased if, for example, ignition is switched off between interrogation and cancellation of fault memory.
  • ‒ Touch "OK" box in display zone -2- of VAS 5051.

"Fault memory erased" appears in display zone -1- as soon as fault memory has been cancelled.

  • ‒ On display of VAS 5051 touch box with ←key.

End of output

 
A87-0314

Requirements:

  • ◆ Fault memory interrogated and erased, basic setting performed and encoding checked => Page 01-107
  • ◆ Currently valid code transmitted by dash panel insert is displayed in measured value block => Page 01-114.

→ Indicated on display of V.A.S 5051:

  • ‒ Select function "06 - End output".

 
A87-0313
  • ‒ → Wait until this display (start menu) appears on VAS 5051.
  • ‒ Switch off ignition and unplug diagnostic connector.

Encoding operating and display unit for air conditioner/Climatronic -E87 (heating) > < Basic setting