Exhaust gas recirculation system - exploded view |
1 - | 25 Nm |
q | Renew |
2 - | Lower connecting pipe for exhaust gas recirculation |
q | When installing, first tighten finger-tight and then tighten to specified torque |
3 - | 22 Nm |
4 - | Gasket |
q | Renew |
5 - | Coolant hoses |
6 - | Exhaust gas recirculation valve -N18- with exhaust gas recirculation potentiometer -G212- |
7 - | 10 Nm |
8 - | O-ring |
q | Renew |
9 - | 10 Nm |
10 - | Air hose |
q | Fitting instructions → Fig. |
11 - | Seal |
q | Renew if damaged or leaking |
12 - | Intake manifold connection |
q | With intake manifold flap motor -V157- |
13 - | O-ring |
q | Renew |
14 - | Intake manifold |
q | Removing and installing → Rep. Gr.23 |
15 - | Gasket |
q | Renew |
16 - | 22 Nm |
17 - | Upper connecting pipe for exhaust gas recirculation |
q | When installing, first tighten finger-tight and then tighten to specified torque |
18 - | 22 Nm |
19 - | Gasket |
q | Renew |
20 - | Gasket |
q | Renew |
q | Note installation position |
21 - | 25 Nm |
22 - | Exhaust gas recirculation cooler |
q | Removing and installing → Chapter |
23 - | 10 Nm |
24 - | Gasket |
q | Renew |
|