l
| No leaks at hose connections. |
–
| Remove combination valve for secondary air system: left-side → Chapter, right-side → Chapter. |
–
| Connect hand vacuum pump -VAS 6213- to vacuum connection -1- of combination valve for secondary air. |
–
| Connect suitable test hose -2- to combination valve for secondary air. |
–
| Blow lightly into test hose -2- with your mouth (do not use compressed air). |
l
| The combination valve for secondary air system should be closed; it should not be possible to blow through the hose. |
–
| Operate hand vacuum pump. |
l
| The combination valve for secondary air system should open; it should now be possible to blow through the hose. |
If combination valve for secondary air does not open: |
–
| Renew combination valve for secondary air system: on left-side → Chapter, on right-side → Chapter. |
|
|
|