Workshop Manuals Factory service & repair Audi
01 Servicing 6-cylinder TDI engine, common rail (EA 897 Gen. I)02 4-cylinder TDI engine, 2.0 ltr. 4-valve common rail (EA 288 Gen. I)03 Servicing 4-cylinder TDI engine, common rail (EA 288 Gen. I)04 6-cylinder TDI engine, 3.0 ltr. 4-valve common rail (EA 897 Gen. I)05 Fuel supply system06 4-cylinder direct injection engine (2.0 ltr. 4-valve TFSI, EA 888 Gen. III, B cycle)07 Servicing 4-cylinder engine, 2.0 ltr. 4-valve TFSI (EA 888, Gen. III BZ)08 4-cylinder direct injection engine (1.8, 2.0 ltr. 4-valve TFSI - generation III)09 4-cylinder direct injection engine (1.4 ltr. 4-valve TFSI, EA 211)10 Technical data for engines11 Servicing 7-speed dual clutch gearbox 0CJ, 0CL, 0CK12 Rear final drive 0D2, 0D3, 0DB13 8-speed automatic gearbox 0D514 7-speed dual clutch gearbox 0CJ, 0CK, 0CL15 6-speed manual gearbox 0CS, 0DJ, 0CX16 Servicing 6-speed manual gearbox 0CS, 0DJ, 0CX17 Running gear: Specifications for testing the braking force (according to German legislation)18 Running gear: Wheel/Tyre Guide19 Brake system20 Running gear, axles, steering21 Heating, air conditioning22 Heating and air conditioning: Auxiliary heater, supplementary heater23 Electrical system24 Electrical: Communication25 General body repairs, interior26 General body repairs, exterior
Audi A4 Mk4 (2015-2023)23 · Electrical system
23 · Electrical

Removing and installing battery

Make
Audi
Model
A4 Mk4
Year
2015–2023
Section
Battery › Removing and installing battery
Electrical systemRemoving and installing battery

Removing and installing battery

Electrical system; General information

If renewing battery, connect battery charger to provide back-up power supply Electrical system; General informationRep. gr.27Charging battery.

Contrary to the following description, the battery must be disconnected with the ignition SWITCHED ON for additional work on pyrotechnic components (e.g. airbags, belt tensioners).After switching off the ignition, wait until the reducing agent has been fully drawn back before performing additional work on the SCR system.

Removing

A27-10579

Switch off ignition.

Lift luggage compartment floor panel.

If fitted, take out spare wheel and mounting for vehicle tool kit.

Remove nut (1) and detach cover (3) with mounting for vehicle tool kit (2).

Remove nuts (3, 4) and bolts (1, 5).

A27-10600

Remove retainer (2).

Open cover (3) over negative battery terminal.

A27-10233

Slacken off nut (1) several turns and disconnect battery clamp (2) of earth cable from battery terminal.

Open cover (1) over positive battery terminal.

A27-10537

Slacken off nut (3) several turns and disconnect battery clamp (2) of positive cable from battery terminal.

Remove bolt (2).

A27-10580

Detach battery retainer plate (1).

Remove battery cover (3).

Pull off hose (5) for central gas venting system.

Lift battery (4) out of luggage compartment.

When disposing of used batteries, observe the required disposal procedures for batteries and sulphuric acid Electrical system; General informationRep. gr.27Battery.

Installing

Note

Batteries from the Audi parts range feature a base strip adapter for matching to different retainer flanges. The battery operating instructions give details of when and how to use the base strip adapter.

Slide battery into retaining bracket (1) as far as stop (arrow), ensuring that battery base strip engages in retaining bracket.

A27-10581
It should no longer be possible to move the battery.

Fit hose for central gas venting system.

Further installation is carried out in the reverse order; note the following:

Connect up battery in the following sequence with ignition and electrical equipment switched off:

First connect battery clamp (2) of positive cable by hand to positive battery terminal “+” and tighten nut (3).

A27-10537

Close cover (1) over positive battery terminal.

Unplug electrical connector (2) at battery monitor control unit J367(item 3).

A27-10252

Attach battery clamp of earth cable to negative battery terminal “–” by hand and tighten nut (1).

Reconnect connector at battery monitor control unit J367.

Check that battery is firmly secured after installing.

If the battery is renewed, the new battery must be adapted.

Procedure

Connect vehicle diagnostic tester.

Select Diagnosis mode and start diagnosis.

Select Test plan tab.

Select Own test then the following options one after the other:

  • Body
  • Electrical system
  • 01 - Self-diagnosis compatible systems
  • 19 - Data bus diagnostic interface - J533
  • 19 - Data bus diagnostic interface, functions
  • 19 - Adaption
  • 19 - Adapt battery

Start the program selected and follow the instructions on the display of the vehicle diagnostic tester.

The following measures are required after re-connecting the battery:

  • Activate automatic open/close function of electric window regulators Owner's Manual for the vehicle.
  • Interrogate event memories of all control units and erase “Low voltage” entry vehicle diagnostic tester.

Note

After reconnecting the voltage supply, it is possible that the ESP warning lamp will not go out until the vehicle has been driven several metres.

Tightening torques

  • Chapter“Exploded view - battery”

Parts & tools for this job For 2015 Audi A4