If renewing battery, connect battery charger to provide back-up power supply Electrical system; General informationRep. gr.27Charging battery.
Contrary to the following description, the battery must be disconnected with the ignition SWITCHED ON for additional work on pyrotechnic components (e.g. airbags, belt tensioners).After switching off the ignition, wait until the reducing agent has been fully drawn back before performing additional work on the SCR system.
Switch off ignition.
Lift luggage compartment floor panel.
If fitted, take out spare wheel and mounting for vehicle tool kit.
Remove nut (1) and detach cover (3) with mounting for vehicle tool kit (2).
Remove nuts (3, 4) and bolts (1, 5).

Remove retainer (2).
Open cover (3) over negative battery terminal.

Slacken off nut (1) several turns and disconnect battery clamp (2) of earth cable from battery terminal.
Open cover (1) over positive battery terminal.

Slacken off nut (3) several turns and disconnect battery clamp (2) of positive cable from battery terminal.
Remove bolt (2).

Detach battery retainer plate (1).
Remove battery cover (3).
Pull off hose (5) for central gas venting system.
Lift battery (4) out of luggage compartment.
When disposing of used batteries, observe the required disposal procedures for batteries and sulphuric acid Electrical system; General informationRep. gr.27Battery.Batteries from the Audi parts range feature a base strip adapter for matching to different retainer flanges. The battery operating instructions give details of when and how to use the base strip adapter.
Slide battery into retaining bracket (1) as far as stop (arrow), ensuring that battery base strip engages in retaining bracket.

Fit hose for central gas venting system.
Further installation is carried out in the reverse order; note the following:
Connect up battery in the following sequence with ignition and electrical equipment switched off:
First connect battery clamp (2) of positive cable by hand to positive battery terminal “+” and tighten nut (3).

Close cover (1) over positive battery terminal.
Unplug electrical connector (2) at battery monitor control unit J367(item 3).

Attach battery clamp of earth cable to negative battery terminal “–” by hand and tighten nut (1).
Reconnect connector at battery monitor control unit J367.
Check that battery is firmly secured after installing.
If the battery is renewed, the new battery must be adapted.
Connect vehicle diagnostic tester.
Select Diagnosis mode and start diagnosis.
Select Test plan tab.
Select Own test then the following options one after the other:
- Body
- Electrical system
- 01 - Self-diagnosis compatible systems
- 19 - Data bus diagnostic interface - J533
- 19 - Data bus diagnostic interface, functions
- 19 - Adaption
- 19 - Adapt battery
Start the program selected and follow the instructions on the display of the vehicle diagnostic tester.
The following measures are required after re-connecting the battery:
- Activate automatic open/close function of electric window regulators Owner's Manual for the vehicle.
- Interrogate event memories of all control units and erase “Low voltage” entry vehicle diagnostic tester.
After reconnecting the voltage supply, it is possible that the ESP warning lamp will not go out until the vehicle has been driven several metres.
- Chapter“Exploded view - battery”
Parts & tools for this job For 2015 Audi A4
- TOOLBattery testerSearch: car battery tester
- TOOLDigital multimeterSearch: automotive digital multimeter
- TOOLBattery terminal cleanerSearch: battery terminal cleaner
As an Amazon Associate we earn from qualifying purchases.