Calibrating matrix LED headlights with headlight adjustment unit VAS 621 001
- Make
- Audi
- Model
- A4 Mk4
- Year
- 2015–2023
- Section
- Headlights › Calibrating matrix LED headlights with headlight adjustment unit VAS 621 001
Calibrating matrix LED headlights with headlight adjustment unit VAS 621 001
The matrix LED headlights are calibrated with the vehicle diagnostic testerVehicle diagnostic tester.
The dipped headlights are adjusted first in this procedure. Afterwards the matrix main beam function is calibrated.
Special tools and workshop equipment requiredHeadlight adjustment unit VAS 621 001

Align VAS 621 001 to centre of vehicle at a distance of (a) = 100 mm Operating instructions of VAS 621 001.
If fitted, pry off cover (1)(arrows).

Ensure that VAS 621 001 is parallel with transverse axis of vehicle. To do so, adjust laser beam of VAS 621 001 so it hits securing bolts for wing at front left and front right (arrows).

Move VAS 621 001 in front of left headlight and perform parallel check again.
To avoid dazzling other road users, ensure that the headlight adjustment unit is aligned properly.Vehicle diagnostic tester is connected.
Select Diagnosis mode and start this mode.
Select Test plan tab.
Select Own test then the following options one after the other:
- Body
- Electrical system
- 01 - Self-diagnosis compatible systems
- 09 - Onboard supply control unit J519
- 09 - Onboard supply control unit, functions
- 09 - Adjust headlights
Start the program selected and follow the instructions on the display of the vehicle diagnostic tester. The dipped headlights must be adjusted first in this procedure Chapter“Adjusting LED headlights”.
During the program, you will be prompted to determine/read off the angle of the inner edge of the segment in the left headlight in the headlight adjustment unit and to enter this into the tester.
Align light collector lens centrally with reference segment of headlight.
Press “§” button (arrow) in main menu of VAS 621001 to start measurement procedure.

Indicated on display:

Press button (arrow) twice and wait for a moment until light measurement is active.
Indicated on display:

Press button (arrow).
Wait for a moment until light measurement has been performed.
Indicated on display:

Enter angle (arrow) of inner edge of reference segment in vehicle diagnostic tester. If necessary, note "+/-" sign.
During the program, you will be prompted to determine/read off the angle of the inner edge of the segment in the right headlight in the headlight adjustment unit and to enter this into the tester.
Align VAS 621 001 to centre of vehicle at a distance of (a) = 100 mm Operating instructions of VAS 621001.

If fitted, pry off cover (1)(arrows).

Ensure that VAS 621 001 is parallel with transverse axis of vehicle. To do so, adjust laser beam of VAS 621 001 so it hits securing bolts for wing at front left and front right (arrows).

Move VAS 621001 in front of right headlight and perform parallel check again.
Align light collector lens centrally with reference segment of headlight.
Indicated on display:

Press button (arrow).
Wait for a moment until light measurement has been performed.
Indicated on display:

Enter angle (arrow) of inner edge of reference segment in vehicle diagnostic tester. If necessary, note "+/-" sign.
After completing calibration, read out event memory and deal with any faults that are present.
Parts & tools for this job For 2015 Audi A4
- PARTReplacement bulbsSearch: Audi A4 2015 bulbs
- TOOLDigital multimeterSearch: automotive digital multimeter
As an Amazon Associate we earn from qualifying purchases.