Workshop Manuals Factory service & repair Audi
01 Servicing 6-cylinder TDI engine, common rail (EA 897 Gen. I)02 4-cylinder TDI engine, 2.0 ltr. 4-valve common rail (EA 288 Gen. I)03 Servicing 4-cylinder TDI engine, common rail (EA 288 Gen. I)04 6-cylinder TDI engine, 3.0 ltr. 4-valve common rail (EA 897 Gen. I)05 Fuel supply system06 4-cylinder direct injection engine (2.0 ltr. 4-valve TFSI, EA 888 Gen. III, B cycle)07 Servicing 4-cylinder engine, 2.0 ltr. 4-valve TFSI (EA 888, Gen. III BZ)08 4-cylinder direct injection engine (1.8, 2.0 ltr. 4-valve TFSI - generation III)09 4-cylinder direct injection engine (1.4 ltr. 4-valve TFSI, EA 211)10 Technical data for engines11 Servicing 7-speed dual clutch gearbox 0CJ, 0CL, 0CK12 Rear final drive 0D2, 0D3, 0DB13 8-speed automatic gearbox 0D514 7-speed dual clutch gearbox 0CJ, 0CK, 0CL15 6-speed manual gearbox 0CS, 0DJ, 0CX16 Servicing 6-speed manual gearbox 0CS, 0DJ, 0CX17 Running gear: Specifications for testing the braking force (according to German legislation)18 Running gear: Wheel/Tyre Guide19 Brake system20 Running gear, axles, steering21 Heating, air conditioning22 Heating and air conditioning: Auxiliary heater, supplementary heater23 Electrical system24 Electrical: Communication25 General body repairs, interior26 General body repairs, exterior
Audi A4 Mk4 (2015-2023)21 · Heating, air conditioning
21 · Heating & A/C

Working on refrigerant circuit

Make
Audi
Model
A4 Mk4
Year
2015–2023
Section
Repair notes › Working on refrigerant circuit
Heating, air conditioningWorking on refrigerant circuit

Working on refrigerant circuit

Always perform work on the refrigerant circuit in well ventilated areas. Make sure that there are no inspection pits, shafts or cellar entrances within a radius of 5 metres. Exhaust gas extraction systems are to be switched on.

Reason:

The refrigerant emerging is not only colourless and odourless, but also heavier than air and thus displaces oxygen. Should refrigerant gas escape even though the safety precautions have been observed, this can result in an imperceptible danger of asphyxiation in poorly ventilated areas and inspection pits.

Note

  • The mixture of gas and air which forms when refrigerant gas escapes must not be inhaled. Use suitable workshop extractors.

Welding, brazing and soldering work must not be performed on components of air conditioning system when charged. This also applies to welding and soldering work on the vehicle if there is a danger of air conditioner components becoming hot.

Reason:

Exposure to heat generates considerable pressure in the system, which could cause it to burst.

Remedy:

Discharge refrigerant circuit Chapter“Discharging refrigerant circuit”.

Note

  • Do not repair damaged or leaking parts of the air conditioner by welding or soldering - they should be renewed.

When servicing the air conditioner, re-seal all open components and pipe connections immediately.

Reason:

Moisture will enter air conditioner components if they are left open for more than a certain amount of time. For this reason, air conditioners which have been left open for a long period cannot be re-charged without renewing parts of the system.

Parts & tools for this job For 2015 Audi A4