Vacuum Solenoid Valve HVAC: Service and Repair

Fresh Air/Recirculating Flap Two- Way Valve -N63-, Removing and Installing

Remove glovebox

-

Remove bolt -A-.

-

Separate electrical connection.

-

Install in reverse order of removal.

NOTE:

-

Connect vacuum hoses correctly (hose - B- to vacuum reservoir, hose -C- to vacuum unit).

-

Vacuum hose layout.

-

Testing -N63-, output Diagnostic Test Mode (DTM).

-

Electrical test.