Page 2
background image

-

Fuel Pump (FP) Control Module J538 OK; check.  See: Powertrain Management/Fuel Delivery and Air Induction/Fuel Pump/Fuel Pump Control
Unit/Testing and Inspection

-

Fuel tank at least 1 / 4 filled.

-

Ignition switched off.

Test sequence

-

Remove rear seat bench.

-

Unbolt cover for left locking flange - arrows - .

-

Disconnect electrical harness connector - arrow - at right locking flange.

-

Connect remote control V.A.G 1348/3 A with connection V.A.G 1348/3-3 to contact - 1 - using an adapter cable from connector test set V.A.G
1594 C .

-

Using insulating tape, tape over the second contact of connection V.A.G 1348/3-3 to prevent a short circuit - arrow - .