No. | Operating sequence |
1 | Full load heating mode (maximum heat output) |
| l
| Coolant temperature in heater less than 77 °C. |
l
| No deviations in measured values and components monitored → Chapter. |
l
| Resistance of flame monitor -G64- in specified range. |
|
| | –
| Combustion air blower -V6- set to full load. |
–
| Clock frequency of metering pump -V54- set to full load. |
–
| Checking of flame formation by flame monitor -G64-. |
|
| | Components | Actuation with | Duration approx. |
| | Combustion air blower -V6- (regulated). | approx. 9 V | Until coolant temperature in heater reaches 77 °C. |
| | Metering pump -V54- (regulated). | approx. 8 Hz | Until coolant temperature in heater reaches 77 °C. |
| | Glow plug for heater -Q9-. | 0 V | - |
| l
| Coolant temperature in heater remains below 77 °C. |
|
| | –
| Heater remains in full load mode until switch-off. |
|
| l
| Coolant temperature in heater reaches 77 °C. |
|
| | –
| Switching from full load to part load mode (coolant temperature in heater reaches 77 °C). |
|
| Possible deviations in full load heating mode (maximum heat output) |
| l
| Voltage drops below specified shutoff voltage. |
–
| Burn-off (entry in event recorder)/fault/off. |
|
| |
2 | Part load operation (approx. 50 % of heat output) |
| 2.1 | Part load mode (diesel) |
| | Switching from full load to part load mode (approx. 50 % of heat output):l
| The coolant temperature in the heater increases and reaches 77 °C. |
l
| No deviations in measured values and components monitored → Chapter. |
l
| Resistance of flame monitor -G64- in specified range. |
|
| | –
| Reduction in voltage at combustion air blower -V6-. |
–
| Reduction in clock frequency of metering pump -V54-. |
–
| Checking of flame formation by flame monitor -G64-. |
–
| Actuation of heater coolant shut-off valve -N279-, governed by temperature → Chapter |
|
| | Components | Actuation with | Duration approx. |
| | Combustion air blower -V6- (regulated). | From approx. 9 V to approx. 6 V | 5 sec. |
| | Metering pump -V54- (regulated). | approx. 4 Hz | 5 sec. |
| | Glow plug for heater -Q9-. | 0 V | - |
| | –
| Combustion air blower -V6- set to part load. |
–
| Clock frequency of metering pump -V54- set to part load. |
–
| Checking of flame formation by flame monitor -G64-. |
|
| | Components | Actuation with | Duration approx. |
| | Combustion air blower -V6- (regulated). | approx. 6 V | Until the coolant temperature in the heater drops below 60 °C or reaches 89 °C |
| | Metering pump -V54- (regulated). | approx. 4 Hz | Until the coolant temperature in the heater drops below 60 °C or reaches 89 °C |
| | Glow plug for heater -Q9-. | 0 V | - |
| l
| Coolant temperature in heater reaches 89 °C. |
|
| | –
| Switching from part load mode to control interval. |
|
| l
| Coolant temperature in heater drops below 60 °C. |
|
| | –
| Switching from part load to full load mode. |
|
| l
| Coolant temperature in heater remains between 60 °C and 89 °C. |
|
| | –
| Heater remains in full load mode until switch-off. |
|
| 2.2 | Part load mode (petrol) |
| | Switching from full load to part load mode (approx. 50 % of heat output):l
| The coolant temperature in the heater increases and reaches 77 °C. |
l
| No deviations in measured values and components monitored → Chapter. |
l
| Resistance of flame monitor -G64- in specified range. |
|
| | –
| Reduction in voltage at combustion air blower -V6-. |
–
| Reduction in clock frequency of metering pump -V54-. |
–
| Checking of flame formation by flame monitor -G64-. |
–
| Actuation of heater coolant shut-off valve -N279-, governed by temperature → Chapter |
|
| | Components | Actuation with | Duration approx. |
| | Combustion air blower -V6- (regulated). | From approx. 9 V to 5 V | 5 sec. |
| | Metering pump -V54- (regulated). | approx. 2 Hz | 5 sec. |
| | Glow plug for heater -Q9-. | 0 V | - |
| | –
| Combustion air blower -V6- set to part load. |
–
| Clock frequency of metering pump -V54- set to part load. |
–
| Checking of flame formation by flame monitor -G64-. |
|
| | Components | Actuation with | Duration approx. |
| | Combustion air blower -V6- (regulated). | 5 V | Until the coolant temperature in the heater drops below 60 °C or reaches 89 °C. |
| | Metering pump -V54- (regulated). | 2 Hz | Until the coolant temperature in the heater drops below 60 °C or reaches 89 °C. |
| | Glow plug for heater -Q9-. | 0 V | - |
| l
| Coolant temperature in heater reaches 89 °C. |
|
| | –
| Switching from part load mode to control interval. |
|
| l
| Coolant temperature in heater drops below 60 °C. |
|
| | –
| Switching from part load to full load mode. |
|
| l
| Coolant temperature in heater remains between 60 °C and 89 °C. |
|
| | –
| Heater remains in full load mode until switch-off. |
|
3 | Control interval |
| l
| The coolant temperature in the heater increases and reaches 89 °C. |
l
| No deviations in measured values and components monitored → Chapter. |
l
| Resistance of flame monitor -G64- in specified range. |
|
| | –
| No regulation of combustion air blower -V6-. |
–
| No regulation of metering pump -V54-. |
–
| No regulation of glow plug for heater -Q9-. |
|
| | Components | Actuation with | Duration approx. |
| | Combustion air blower -V6-. | 0 V | - |
| | Metering pump -V54-. | 0 Hz | - |
| | Glow plug for heater -Q9-. | 0 V | - |
| l
| Coolant temperature in heater remains above 65 °C. |
–
| Heater remains in control interval until switch-off. |
|
| l
| Coolant temperature in heater drops below 65 °C. |
|