Workshop Manuals Factory service & repair Audi
01 6-cylinder TDI engine (2.7 ltr.; 3.0 ltr. 4-valve common rail)02 Fuel supply system, diesel engines03 Fuel supply system, petrol engines04 6-cylinder direct petrol injection engine (3.2 ltr. 4-valve)05 4-cylinder TDI engine (2.0 ltr. 4-valve common rail)06 4-cylinder direct injection engine (1.8, 2.0 ltr. 4-valve - generation II)07 6-cylinder direct injection engine with supercharger (3.0 ltr. 4-valve TFSI)08 4-cylinder TDI engine (2.0 ltr. 4-valve common rail - generation II)09 4-cylinder direct injection engine (1.8, 2.0 ltr. 4-valve TFSI - generation III)10 6-cylinder TDI engine (3.0 ltr. 4-valve common rail - generation II)11 4-cylinder TDI engine, 2.0 ltr. 4-valve common rail (EA 288 Gen. I)12 6-cylinder direct injection engine (evo) with supercharger (3.0 ltr. 4-valve TFSI)13 Engine: TDI injection and glow plug system (6-cyl. 2.7 ltr., 3.0 ltr. 4-valve common rail)14 Direct petrol injection and ignition system (8-cyl. 4.2 ltr. 4-valve), RS 4, RS 515 8-cylinder direct injection engine (4.2 ltr. 4-valve, RS 4, RS 5)16 Technical data for engines17 Simos direct petrol injection and ignition system (6-cyl. 3.2 ltr. 4-valve)18 6-speed manual gearbox 0B2, four-wheel drive19 Rear final drive 0BC, 0BD, 0BE, 0BF20 Servicing 6-speed manual gearbox 0B2, four-wheel drive21 Servicing 6-speed manual gearbox 0B1, front-wheel drive22 Gearbox: Servicing multitronic 0AW23 Servicing 7-speed dual clutch gearbox 0B5 (S tronic)24 6-speed manual gearbox 0B1, front-wheel drive25 Gearbox: multitronic 0AW, front-wheel drive26 6-speed manual gearbox 0B3, front-wheel drive27 7-speed dual clutch gearbox 0B5 (S tronic)28 8-speed automatic gearbox 0BK, four-wheel drive29 Automatic gearbox 0B6, four-wheel drive30 Servicing 6-speed manual gearbox 0B3, front-wheel drive31 Running gear: Specifications for testing the braking force (according to German legislation)32 Running gear: Trailer Operation Guide33 Running gear, axles, steering34 Brake system35 Running gear: Wheel/Tyre Guide36 Heating, air conditioning37 Electrical: System description - adaptive cruise control38 Electrical: System description - infotainment and navigation system39 System description - infotainment and audio output (MOST)40 Electrical: System description - entry and start authorisation41 Electrical system42 Electrical: Communication43 General body repairs, exterior44 General body repairs, interior
Audi A5 Cabriolet (2009-2017)36 · Heating, air conditioning
36 · Heating & A/C

Safety precautions when handling refrigerants

Make
Audi
Model
A5 Cabriolet
Year
2009–2017
Section
Safety precautions › Safety precautions when handling refrigerants
Heating, air conditioningSafety precautions when handling refrigerants

Safety precautions when handling refrigerants

The components and piping system of the air conditioner are filled with the following refrigerant:

1.1.1 2-tetrafluoroethane (CF3-CH2F or CH2F-CF3)

This refrigerant is currently known in Germany by the trade names R134a, H-FKW 134a, SUVA 134a and KLEA 134a (other trade names may be used in other countries).

In Germany, observe the following safety measures for this refrigerant (additional regulations may apply in other countries).

The refrigerant circuit must be discharged first should repair work require the refrigerant circuit to be opened → Chapter. All contact with liquid refrigerant or refrigerant vapours should be avoided. Should refrigerant escape although all safety precautions are observed, do not inhale the mixture of refrigerant and air which then forms.

For this reason, switch on existing exhaust gas extraction systems and use rubber gloves and safety goggles.

Reason:

Intensive exposure to refrigerant would cause frostbite on unprotected parts of the body.

Warning Keep an eye-bath to hand.
Should liquid refrigerant come into contact with the eyes, rinse them thoroughly with water for about 15 minutes.
Then apply eye drops and consult a doctor immediately, even if you do not experience any pain in the eyes.
Always inform the doctor of the type of refrigerant involved.

Should refrigerant come into contact with other parts of the body even though all safety precautions have been observed, these components must also be thoroughly rinsed with cold water immediately for at least 15 minutes.

Although refrigerants do not represent a fire hazard, smoking, welding, soldering and brazing are not permitted in areas exposed to refrigerant.

Reason:

The high temperature of a naked flame or hot objects causes decomposition of refrigerant gas. Inhalation of the toxic decomposition products causes dry coughing and nausea.

Parts & tools for this job For 2009 Audi A5

As an Amazon Associate we earn from qualifying purchases.