01 6-cylinder TDI engine (2.7 ltr.; 3.0 ltr. 4-valve common rail)02 Fuel supply system, diesel engines03 6-cylinder direct petrol injection engine (3.2 ltr. 4-valve)04 6-cylinder direct injection engine with supercharger (3.0 ltr. 4-valve TFSI)05 6-cylinder TDI engine (3.0 ltr. 4-valve common rail - generation II)06 6-cylinder direct injection engine (evo) with supercharger (3.0 ltr. 4-valve TFSI)07 Running gear, axles, steering08 Heating, air conditioning09 Heating and air conditioning: Auxiliary heater, supplementary heater10 Electrical: Communication11 General body repairs, interior12 General body repairs, exterior
Audi A5 Sportback (2009-2016)10 · Electrical: Communication
10 · Electrical

Calibrating reversing camera R189

Make
Audi
Model
A5 Sportback
Year
2009–2016
Section
Reversing camera system › Calibrating reversing camera R189
Electrical: CommunicationCalibrating reversing camera R189

Calibrating reversing camera R189

Ensure requirements are met Anchor.

Connect Vehicle diagnostic tester.

Fit wheel centre mounting VAS 6350/1:

Check the bolt hole circle pattern on the wheels.

Prepare wheel centre mountings VAS 6350/1 as required.

To do so, secure three wheel bolt adapters to each wheel centre mounting VAS 6350/1 to match the hole circle.

Position paddles on both wheel centre mountings VAS 6350/1 and secure each paddle with clamping bolt.

Fit wheel centre mountings VAS 6350/1 onto wheel bolts on rear wheels.

The wheel centre mountings VAS 6350/1 are kept in position by the O-rings in the adapters.

N94-10685

Note

  • When fitting the wheel centre mountings VAS 6350/1 onto the wheels, make sure that they are not mounted on any “anti-theft” wheel bolts that might be installed.

Using clamping bolts, adjust paddles so that they are free to move just slightly above the ground. Make sure the paddles can move freely.

Set up and align calibration unit VAS 6350/4Chapter.

Measuring gap:

Switch on the spacing laser VAS 6350/2 with the ON button.

The following display appears and the spacing laser VAS 6350/2 will be switched on.

N94-10681

Hold spacing laser VAS 6350/2(2) on one side of calibration unit VAS 6350/4 so that it is flush at bracket. Spacing laser VAS 6350/2(2) must make firm contact with bracket.

N94-10684

Make sure that laser beam from spacing laser VAS 6350/2(2) hits lower, larger part of paddle (1).

If this is not the case, position of paddles must be corrected accordingly using clamping bolts on wheel centre mounting VAS 6350/1.

Hold spacing laser VAS 6350/2 in locating bracket on calibration unit VAS 6350/4 with one hand while laser beam is visible on paddle.

Briefly operate the ON button to measure distance.

Display readout

N94-10682

Make a note of the displayed value.

Perform same measuring procedure for rear wheel on other side of calibration unit VAS 6350/4.

Measured distance value must be identical on both sides.

If values are not identical:

Adjust calibration unit VAS 6350/4 until values on both sides are identical.

When adjusting calibration unit VAS 6350/4, make sure that linear laser VAS 6350/3 on calibration unit VAS 6350/4 still hits centre of Audi rings and spirit level display also remains in the centre. If necessary, readjust.

Measuring dimension (H):

Measure height of calibration unit VAS 6350/4: dimension (H) (top edge of platform - floor).

A91-11140

Now enter measured distance value and height in millimetres in Vehicle diagnostic tester.

Performing calibration

Vehicle diagnostic tester is connected.

Select Guided Fault Finding mode.

In the “Vehicle selection” menu, select the relevant data for the vehicle.

Using the Go to button, select the following menu options in succession:

  • Selecting function/component
  • Body
  • Electrical system
  • 01 - Self-diagnosis compatible systems
  • 6C - Reversing camera system/J772
  • 6C - Reversing camera system control unit, functions
  • 6C - Calibration (Rep. gr. 91)

Further instructions are given by Vehicle diagnostic tester during calibration procedure.

Warning Make sure no light is reflected on calibration platform.
Reflected light impairs the view of the reversing camera R189 and therefore it may be impossible to perform calibration.