Notes on refrigerant circuit
- Make
- Audi
- Model
- A5 Sportback
- Year
- 2009–2016
- Section
- General notes › Notes on refrigerant circuit
Notes on refrigerant circuit
For all work on vehicles with a high-voltage system, note the additional warning instructions for working on such vehicles → Chapter and Electrical systemRep. gr.93General warning instructions for work on the high-voltage system.
Warning Safety hazard: the engine can start unexpectedly.
Before carrying out general work on a vehicle with high-voltage electrical system, switch off the ignition and remove the ignition key from the vehicle.
Warning Working on vehicles with high-voltage wiring:
Do not support yourself or tools on high-voltage wiring or associated components --> this can damage the insulation. High-voltage wiring must not be excessively bent or kinked --> this can damage the insulation. The round high-voltage connectors are colour-coded with an external coloured ring and are provided with mechanical coding or guide lugs. It is important to observe this coding when joining up the round high-voltage connectors, otherwise the connectors can be damaged.
Warning DANGER!Risk of fatal injury if high-voltage components are damaged.
Observe the following when working in the vicinity of high-voltage components or wiring:
- It is not permitted to use cutting or forming tools, other sharp-edged tools or heat sources such as welding, brazing, soldering, hot air or thermal bonding equipment.
- Before starting work, visually inspect the high-voltage components in the areas involved.
- Before working in the engine compartment, visually inspect the power and control electronics for electric drive JX1, electric drive motor V141, air conditioner compressor V470 and high-voltage wiring.
- Before working on the vehicle underbody, visually inspect the high-voltage wiring and covers.
- Before working on the rear section of the vehicle, visually inspect the high-voltage wiring and the electro-box with the maintenance connector for high-voltage system TW .
- Visually inspect all potential equalisation lines.
- There must be no external damage on any component.
- The insulation of the high-voltage wiring and potential equalisation lines must not be damaged.
- There must be no unusual deformation of the high-voltage wiring.
- All high-voltage components must be identified by a red warning sticker.
If work is necessary in the vicinity of high-voltage system components, perform a visual inspection of the high-voltage components and wiring to check for damage → Chapter and note Electrical systemRep. gr.93General warning instructions for work on the high-voltage system.
If work is necessary on components of the high-voltage system, de-energise the high-voltage system Electrical systemRep. gr.93De-energising high-voltage system and note Electrical systemRep. gr.93General warning instructions for work on the high-voltage system.
Note
- The control unit for air conditioning compressor J842 integrated into the electrically driven air conditioner compressor regulates the speed and thus the output of the air conditioner compressor (electrical air conditioner compressor V470).
Note
- The air conditioner compressor without air conditioning system magnetic clutch N25 is always driven when the engine is running. On vehicles with an air conditioner compressor without N25, it is therefore important not to start the engine unless the refrigerant circuit has been properly assembled. If, for example, the refrigerant lines are not connected to the air conditioner compressor when the engine is running, the compressor might heat up (internal heat generation) so much that this can lead to irreparable damage to the compressor. The internal heat generation is caused by the air conditioner compressor operating against a fixed resistance even at approximately 0 % delivery rate (sealed circuit).
- From model year 2012 onwards, air conditioner compressors with an additional air conditioning system magnetic clutch N25 fitted are gradually being introduced for certain vehicles with 4-cyl. engines → Chapter. In certain air conditioner operating modes (e.g. “Econ” mode), the air conditioner compressor drive system is completely deactivated via this magnetic clutch. For N25 to be activated by the operating and display unit (Climatronic control unit J255), the correct version of J255 must be fitted and correctly encoded Electronic parts catalogue and Vehicle diagnostic, testing and information system VAS 5051/ ("Guided Fault Finding").
- To prevent the air conditioner compressor from being damaged irreparably when the refrigerant circuit is empty, it is designed so that delivery is reduced to roughly 0 % and lubrication is maintained via an internal oil circuit with the residual oil left in the air conditioner compressor.
Note
- Never top up the refrigerant in the refrigerant circuit (discharge, evacuate and re-charge circuit) Air conditioner with refrigerant R134aRep. gr.87Refrigerant circuit; Working with the air conditioner service station.
- Replacement compressors contain the full quantity of refrigerant oil required for the refrigerant circuit Air conditioner with refrigerant R134aRep. gr.87Capacities for refrigerant R134a/refrigerant oil and approved refrigerant oils.
- Different refrigerant oils are specified for Denso, Sanden and Zexel/Valeo air conditioner compressors Air conditioner with refrigerant R134aRep. gr.87Capacities for refrigerant R134a/refrigerant oil and approved refrigerant oils, and Electronic parts catalogue.
- Lubricate O-rings lightly with refrigerant oil before fitting → Chapter.
- The specified O-ring diameters and the tightening torques also apply to the bolt connections of the refrigerant lines and refrigerant hoses between the individual components.
- Only fit O-rings approved for refrigerant R134a → Chapter, Air conditioner with refrigerant R134aRep. gr.87General notes on air conditioning systems and Electronic parts catalogue.
- Checking cooling output → Chapter
- Checking pressures in refrigerant circuit Air conditioner with refrigerant R134aRep. gr.87Refrigerant circuit; Working with the air conditioner service station
- For all other refrigerant circuit servicing and testing work not described in this Workshop Manual, refer to Air conditioner with refrigerant R134aRep. gr.87General notes on air conditioning systems.
- Starting up air conditioner after charging refrigerant circuit → Chapter
- From the start of production up to the conversion from model year 2012 onwards, evaporators with a width (block depth) of approx. 40 mm were fitted (air conditioning unit with part number “8K_ 820 005”). From model year 2012 onwards and depending on the vehicle version, evaporators with a width (block depth) of approx. 50 mm are being introduced gradually (air conditioning unit with part number “8T_ 820 005”). Pay attention to the correct assignment of the expansion valve to the evaporator (different versions) Electronic parts catalogue.
Parts & tools for this job For 2009 Audi A5
- TOOLA/C manifold gauge setSearch: AC manifold gauge set
- TOOLUV leak detection kitSearch: AC UV leak detection kit
- PARTCabin filterSearch: Audi A5 2009 cabin filter
As an Amazon Associate we earn from qualifying purchases.