01 6-cylinder TDI engine (2.7 ltr.; 3.0 ltr. 4-valve common rail)02 Fuel supply system, diesel engines03 6-cylinder direct petrol injection engine (3.2 ltr. 4-valve)04 6-cylinder direct injection engine with supercharger (3.0 ltr. 4-valve TFSI)05 6-cylinder TDI engine (3.0 ltr. 4-valve common rail - generation II)06 6-cylinder direct injection engine (evo) with supercharger (3.0 ltr. 4-valve TFSI)07 Running gear, axles, steering08 Heating, air conditioning09 Heating and air conditioning: Auxiliary heater, supplementary heater10 Electrical: Communication11 General body repairs, interior12 General body repairs, exterior
Audi A5 Sportback (2009-2016)08 · Heating, air conditioning
08 · Heating & A/C

Safety precautions when handling refrigerants

Make
Audi
Model
A5 Sportback
Year
2009–2016
Section
Safety precautions › Safety precautions when handling refrigerants
Heating, air conditioningSafety precautions when handling refrigerants

Safety precautions when handling refrigerants

The components and piping system of the air conditioner are filled with the following refrigerant:

1.1.1 2-tetrafluoroethane (CF3-CH2F or CH2F-CF3)

This refrigerant is currently known in Germany by the trade names R134a, H-FKW 134a, SUVA 134a and KLEA 134a (other trade names may be used in other countries).

In Germany, observe the following safety measures for this refrigerant (additional regulations may apply in other countries).

The refrigerant circuit must be discharged first should repair work require the refrigerant circuit to be opened → Chapter. All contact with liquid refrigerant or refrigerant vapours should be avoided. Should refrigerant escape although all safety precautions are observed, do not inhale the mixture of refrigerant and air which then forms.

For this reason, switch on existing exhaust gas extraction systems and use rubber gloves and safety goggles.

Reason:

Intensive exposure to refrigerant would cause frostbite on unprotected parts of the body.

Warning Keep an eye-bath to hand.
Should liquid refrigerant come into contact with the eyes, rinse them thoroughly with water for about 15 minutes.
Then apply eye drops and consult a doctor immediately, even if you do not experience any pain in the eyes.
Always inform the doctor of the type of refrigerant involved.

Should refrigerant come into contact with other parts of the body even though all safety precautions have been observed, these components must also be thoroughly rinsed with cold water immediately for at least 15 minutes.

Although refrigerants do not represent a fire hazard, smoking, welding, soldering and brazing are not permitted in areas exposed to refrigerant.

Reason:

The high temperature of a naked flame or hot objects causes decomposition of refrigerant gas. Inhalation of the toxic decomposition products causes dry coughing and nausea.