Test table
- Make
- Audi
- Model
- A6 C5
- Year
- 1997–2004
- Section
- Electrical check › Test table
‹ Prev Connecting adapter V.A.G 1598/20 (test box) to automatic gearbox control unit J217Next › Checking wiring between automatic gearbox control unit J217 and gearbox
Automatic gearbox 01L, self-diagnosisTest table
Test table
| Component to be checked | Test step |
|---|---|
| Voltage supply for automatic gearbox control unit J217 | Perform test steps No. 1 Anchor and No. 5 Anchor |
| Selector lever lock solenoid N110 | Perform test steps No. 2 Anchor and No. 15 Anchor |
| Multi-function switch F125 | Perform test steps No. 3 Anchor and No. 4 Anchor |
| Solenoid valve 1 N88 | Perform test steps No. 6 Anchor and No. 7 Anchor |
| Solenoid valve 2 N89 | Perform test steps No. 6 Anchor and No. 8 Anchor |
| Solenoid valve 3 N90 | Perform test steps No. 6 Anchor and No. 9 Anchor |
| Automatic gearbox pressure regulating valve 1 N215 | Perform test steps No. 6 Anchor and No. 10 Anchor |
| Automatic gearbox pressure regulating valve 2 N216 | Perform test steps No. 6 Anchor and No. 11 Anchor |
| Automatic gearbox pressure regulating valve 3 N217 | Perform test steps No. 6 Anchor and No. 12 Anchor |
| Automatic gearbox pressure regulating valve 4 N218 | Perform test steps No. 6 Anchor and No. 13 Anchor |
| Automatic gearbox pressure regulating valve 5 N233 | Perform test steps No. 6 Anchor and No. 14 Anchor |
| Gearbox output speed sender G195 | Perform test step No. 16 Anchor |
| Gearbox input speed sender G182 | Perform test step No. 17 Anchor |
| Gearbox oil temperature sender G93 (ATF) | Perform test step No. 18 Anchor |
| tiptronic switch F189 (only applies to vehicles up to model year 2001) | Perform test steps No. 19 Anchor and No. 20 Anchor |
| V.A.G 1598/20 sockets | Items tested | Test conditions and additional steps | Specification | Fault rectification if readout does not match specification |
|---|---|---|---|---|
| 26 + 6 26 + 28 Note 26 + 34 | Voltage supply (terminal 30) for automatic gearbox control unit J217 | Ignition switched off | ||
| Switch to voltage measuring range | Approx. battery voltage | Check wiring according to current flow diagram:From contact 26 to terminal 30From contacts 6, 28 and 34 to earth | ||
| 55 + 6 55 + 28 Note 55 + 34 | Voltage supply (terminal 15) for automatic gearbox control unit J217 | Switch on ignition | Approx. battery voltage | Check wiring according to current flow diagram:From contact 55 or 54 to terminal 15From contacts 6, 28 and 34 to earth |
| 55 + 54 | 0 V |
Note
| V.A.G 1598/20 sockets | Items tested | Test conditions and additional steps | Specification | Fault rectification if readout does not match specification |
|---|---|---|---|---|
| 2 + 6 | Selector lever lock solenoid N110 | Ignition switched on | ||
| Switch to voltage measuring range | Approx. battery voltage | Check wiring according to current flow diagram Check multi-function switch F125 for short circuitCheck selector lever lock solenoid N110 for short circuitPerform test step No. 15 Anchor |
| V.A.G 1598/20 sockets | Items tested | Test conditions and additional steps | Specification | Fault rectification if readout does not match specification |
|---|---|---|---|---|
| 36 + 6 | Multi-function switch F125 | Ignition switched onSwitch to voltage measuring range | ||
| Selector lever in “P”, “N”, “D” | Approx. battery voltage | Check multi-function switch connector for contact corrosionCheck multi-function switch Chapter“Checking multi-function switch F125 with 8-pin connector” or Chapter“Checking multi-function switch F125 with 10-pin connector”Perform test step No. 4 Anchor | ||
| Selector lever in “R”, “S” or “4”, “3”, “2” | Less than 1 V | |||
| 8 + 6 | Selector lever in “R”, “N”, “S” or “4” | Approx. battery voltage | ||
| Selector lever in “P”, “D”, “3”, “2” | Less than 1 V | |||
| 37 + 6 | Selector lever in “N”, “D”, “S” or “4”, “2” | Approx. battery voltage | ||
| Selector lever in “P”,“R”, “3” | Less than 1 V | |||
| 9 + 6 | Selector lever in “D”, “S” or “4”, “3” | Approx. battery voltage | ||
| Selector lever in “P”, “R”, “N”, “2” | Less than 1 V |
| V.A.G 1598/20 sockets | Items tested | Test conditions and additional steps | Specification | Fault rectification if readout does not match specification |
|---|---|---|---|---|
| 36 + 55 | Multi-function switch F125 | Ignition switched offSwitch to resistance measuring range | ||
| Selector lever in “P”, “N”, “D” | Less than 1 Ω | Check multi-function switch connector for contact corrosionCheck multi-function switch Chapter“Checking multi-function switch F125 with 8-pin connector” or Chapter“Checking multi-function switch F125 with 10-pin connector”Perform test step No. 3 Anchor | ||
| Selector lever in “P”, “R”, “D”, “S” or “4”, “3”, “2” | ∞ Ω | |||
| 8 + 55 | Selector lever in “R”, “N”, “S” or “4” | Less than 1 Ω | ||
| Selector lever in “P”, “D”, “3”, “2” | ∞ Ω | |||
| 37 + 55 | Selector lever in “N”, “D”, “S” or “4”, “2” | Less than 1 Ω | ||
| Selector lever in “P”,“R”, “3” | ∞ Ω | |||
| 9 + 55 | Selector lever in “D”, “S” or “4”, “3” | Less than 1 Ω | ||
| Selector lever in “P”, “R”, “N”, “2” | ∞ Ω |
| V.A.G 1598/20 sockets | Items tested | Test conditions and additional steps | Specification | Fault rectification if readout does not match specification |
|---|---|---|---|---|
| 6 + earth at battery | Earth connections for automatic gearbox control unit J217 | Ignition switched off | ||
| Switch to resistance measuring range | Less than 1 Ω | Check wiring according to current flow diagram | ||
| 28 + earth at battery | Less than 1 Ω | |||
| 34 + earth at battery | Less than 1 Ω |
| V.A.G 1598/20 sockets | Items tested | Test conditions and additional steps | Specification | Fault rectification if readout does not match specification |
|---|---|---|---|---|
| 52 + 53 | Voltage supply wires to solenoid valves | Ignition switched off | ||
| Switch to resistance measuring range | ||||
| Up to model year 2001 | Less than 1 Ω | Check wiring according to current flow diagramCheck wiring from automatic gearbox control unit J217 to 16-pin connector ChapterPerform test step No. 1 AnchorCheck wiring harness in gearbox according to current flow diagram; renew if necessary | ||
| From model year 2002 | ∞ Ω |
| V.A.G 1598/20 sockets | Items tested | Test conditions and additional steps | Specification | Fault rectification if readout does not match specification |
|---|---|---|---|---|
| 30 + 52 | Solenoid valve 1 N88 | Ignition switched off | ||
| Switch to resistance measuring range | 25 … 35 Ω | Check 16-pin connector to gearbox for contact corrosionPerform test step No. 6 AnchorCheck wiring from automatic gearbox control unit J217 to 16-pin connector ChapterCheck wiring harness in gearbox according to current flow diagram; renew if necessaryRenew solenoid valve Automatic gearbox 01L, four-wheel driveRep. Gr.38 | ||
| 30 + 34 | ∞ Ω |
| V.A.G 1598/20 sockets | Items tested | Test conditions and additional steps | Specification | Fault rectification if readout does not match specification |
|---|---|---|---|---|
| 33 + 52 | Solenoid valve 2 N89 | Ignition switched off | ||
| Switch to resistance measuring range | 25 … 35 Ω | Check 16-pin connector to gearbox for contact corrosionPerform test step No. 6 AnchorCheck wiring from automatic gearbox control unit J217 to 16-pin connector ChapterCheck wiring harness in gearbox according to current flow diagram; renew if necessaryRenew solenoid valve Automatic gearbox 01L, four-wheel driveRep. Gr.38 | ||
| 33 + 34 | ∞ Ω |
| V.A.G 1598/20 sockets | Items tested | Test conditions and additional steps | Specification | Fault rectification if readout does not match specification |
|---|---|---|---|---|
| 32 + 52 | Solenoid valve 3 N90 | Ignition switched off | ||
| Switch to resistance measuring range | 25 … 35 Ω | Check 16-pin connector to gearbox for contact corrosionPerform test step No. 6 AnchorCheck wiring from automatic gearbox control unit J217 to 16-pin connector ChapterCheck wiring harness in gearbox according to current flow diagram; renew if necessaryRenew solenoid valve Automatic gearbox 01L, four-wheel driveRep. Gr.38 | ||
| 32 + 34 | ∞ Ω |
| V.A.G 1598/20 sockets | Items tested | Test conditions and additional steps | Specification | Fault rectification if readout does not match specification |
|---|---|---|---|---|
| 5 + 52 | Automatic gearbox pressure regulating valve 1 N215 | Ignition switched off | ||
| Switch to resistance measuring range | 6 … 10 Ω | Check 16-pin connector to gearbox for contact corrosionPerform test step No. 6 AnchorCheck wiring from automatic gearbox control unit J217 to 16-pin connector ChapterCheck wiring harness in gearbox according to current flow diagram; renew if necessaryRenew solenoid valve Automatic gearbox 01L, four-wheel driveRep. Gr.38 | ||
| 5 + 34 | ∞ Ω |
| V.A.G 1598/20 sockets | Items tested | Test conditions and additional steps | Specification | Fault rectification if readout does not match specification |
|---|---|---|---|---|
| 1 + 53 | Automatic gearbox pressure regulating valve 2 N216 | Ignition switched off | ||
| Switch to resistance measuring range | 6 … 10 Ω | Check 16-pin connector to gearbox for contact corrosionPerform test step No. 6 AnchorCheck wiring from automatic gearbox control unit J217 to 16-pin connector ChapterCheck wiring harness in gearbox according to current flow diagram; renew if necessaryRenew solenoid valve Automatic gearbox 01L, four-wheel driveRep. Gr.38 | ||
| 1 + 34 | ∞ Ω |
| V.A.G 1598/20 sockets | Items tested | Test conditions and additional steps | Specification | Fault rectification if readout does not match specification |
|---|---|---|---|---|
| 29 + 53 | Automatic gearbox pressure regulating valve 3 N217 | Ignition switched off | ||
| Switch to resistance measuring range | 6 … 10 Ω | Check 16-pin connector to gearbox for contact corrosionPerform test step No. 6 AnchorCheck wiring from automatic gearbox control unit J217 to 16-pin connector ChapterCheck wiring harness in gearbox according to current flow diagram; renew if necessaryRenew solenoid valve Automatic gearbox 01L, four-wheel driveRep. Gr.38 | ||
| 29 + 34 | ∞ Ω |
| V.A.G 1598/20 sockets | Items tested | Test conditions and additional steps | Specification | Fault rectification if readout does not match specification |
|---|---|---|---|---|
| 4 + 52 | Automatic gearbox pressure regulating valve 4 N218 | Ignition switched off | ||
| Switch to resistance measuring range | 6 … 10 Ω | Check 16-pin connector to gearbox for contact corrosionPerform test step No. 6 AnchorCheck wiring from automatic gearbox control unit J217 to 16-pin connector ChapterCheck wiring harness in gearbox according to current flow diagram; renew if necessaryRenew solenoid valve Automatic gearbox 01L, four-wheel driveRep. Gr.38 | ||
| 4 + 34 | ∞ Ω |
| V.A.G 1598/20 sockets | Items tested | Test conditions and additional steps | Specification | Fault rectification if readout does not match specification |
|---|---|---|---|---|
| 51 + 53 | Automatic gearbox pressure regulating valve 5 N233 | Ignition switched off | ||
| Switch to resistance measuring range | 6 … 10 Ω | Check 16-pin connector to gearbox for contact corrosionPerform test step No. 6 AnchorCheck wiring from automatic gearbox control unit J217 to 16-pin connector ChapterCheck wiring harness in gearbox according to current flow diagram; renew if necessaryRenew solenoid valve Automatic gearbox 01L, four-wheel driveRep. Gr.38 | ||
| 51 + 34 | ∞ Ω |
| V.A.G 1598/20 sockets | Items tested | Test conditions and additional steps | Specification | Fault rectification if readout does not match specification |
|---|---|---|---|---|
| 2 + 54 | Selector lever lock solenoid N110 | Ignition switched offSelector lever at position “P” | ||
| Switch to resistance measuring range | 14 … 28 Ω | Check wiring according to current flow diagramRenew selector lever lock solenoid Automatic gearbox 01L, four-wheel driveRep. Gr.37 |
| V.A.G 1598/20 sockets | Items tested | Test conditions and additional steps | Specification | Fault rectification if readout does not match specification |
|---|---|---|---|---|
| 14 + 42 | Gearbox output speed sender G195 | Ignition switched off | ||
| Switch to resistance measuring range | Min. 0.8 kΩ | Check wiring according to current flow diagramRenew gearbox output speed sender Automatic gearbox 01L, four-wheel driveRep. Gr.38 | ||
| Max. 1.2 kΩ | ||||
| 14 + 34 14 + 54 42 + 54 42 + 34 | ∞ Ω | |||
| 15 + 34 15 + 54 | Screening for gearbox output speed sender G195 | ∞ Ω | Check wiring according to current flow diagram |
| V.A.G 1598/20 sockets | Items tested | Test conditions and additional steps | Specification | Fault rectification if readout does not match specification |
|---|---|---|---|---|
| 16 + 44 | Gearbox input speed sender G182 | Ignition switched off88-pin connector disconnected from control unit | ||
| Switch to resistance measuring range | Min. 230 Ω | Check wiring according to current flow diagramRenew gearbox input speed sender Automatic gearbox 01L, four-wheel driveRep. Gr.38 | ||
| Max. 300 Ω | ||||
| 44 + 34 44 + 54 16 + 54 16 + 34 | ∞ Ω | |||
| 23 + 34 23 + 54 | Screening for gearbox input speed sender G182 | ∞ Ω | Check wiring according to current flow diagram |
| V.A.G 1598/20 sockets | Items tested | Test conditions and additional steps | Specification | Fault rectification if readout does not match specification | |
|---|---|---|---|---|---|
| 21 + 22 | Gearbox oil temperature sender G93 (ATF) | Ignition switched offSwitch to resistance measuring range | |||
| Measure ATF temperature | |||||
| Approx. 20 °C | Approx. 0.83 kΩNote | Check wiring from automatic gearbox control unit J217 to 16-pin connector ChapterCheck wiring harness in gearbox according to current flow diagram; renew if necessary (the gearbox oil (ATF) temperature sender is integrated in wiring harness) Automatic gearbox 01L, four-wheel driveRep. Gr.38 | |||
| Approx. 60 °C | Approx. 1.28 kΩNote | ||||
| Approx. 120 °C | Approx. 1.88 kΩNote | ||||
| 21 + 34 22 + 34 | ∞ Ω | ||||
| 21 + 54 22 + 54 | ∞ Ω |
Note
| V.A.G 1598/20 sockets | Items tested | Test conditions and additional steps | Specification | Fault rectification if readout does not match specification |
|---|---|---|---|---|
| 13 + 34 | tiptronic switch F189 (recognition) | Ignition switched offSwitch to resistance measuring range | ||
| Selector lever not in tiptronic gate | ∞ Ω | In the event of malfunctions in the tiptronic switch, first check that magnet is properly secured at the side of the transverse slide of sliding cover. If not, sliding cover must be renewedCheck voltage supply for selector mechanism cover ChapterCheck wiring according to current flow diagram If the magnet is secured properly and the wiring is OK, renew selector mechanism cover with tiptronic switch Automatic gearbox 01L, four-wheel driveRep. Gr.37 | ||
| Selector lever in tiptronic gate | Less than 10 Ω |
| V.A.G 1598 A sockets | Items tested | Test conditions and additional steps | Specification | Fault rectification if readout does not match specification |
|---|---|---|---|---|
| 46 + 34 47 + 34 | tiptronic switch F189 (shift up/shift down) | Ignition switched offSwitch to resistance measuring range | ||
| Shift up button (+) or shift down button (–) not operated | ∞ Ω | Check voltage supply for selector mechanism cover ChapterCheck wiring according to current flow diagramRenew tiptronic switch Automatic gearbox 01L, four-wheel driveRep. Gr.37 | ||
| 46 + 34 | Operate shift up button (+) and at the same time keep selector lever pressed forwards or press and hold the upper button on the left or right (+) of multi-function steering wheel | Less than 10 Ω | ||
| 47 + 34 | Operate shift down button (–) and at the same time keep selector lever pressed towards the rear or press and hold the lower button on the left or right (–) of multi-function steering wheel | Less than 10 Ω |
‹ Prev Connecting adapter V.A.G 1598/20 (test box) to automatic gearbox control unit J217Next › Checking wiring between automatic gearbox control unit J217 and gearbox