Self-diagnosis function
- Make
- Audi
- Model
- A6 C5
- Year
- 1997–2004
- Section
- Self-diagnosis › Self-diagnosis function
Automatic gearbox 01L, self-diagnosisSelf-diagnosis function
Self-diagnosis function
- The automatic gearbox is controlled electro-hydraulically.
- The automatic gearbox control unit J217 is supplied with information from components which influence gear selection. With this information the control unit generates signals to control the relevant solenoid valves in the valve body. The solenoid valves direct the fluid pressure produced by the ATF pump to close the appropriate brakes in the gearbox.
- The term “self-diagnosis” relates specifically to the electrical and electronic part of the control system.
- The control unit detects faults during vehicle operation and stores them in a fault memory Chapter“Fault tables”.
- Before starting fault-finding procedure, always initiate self-diagnosis and interrogate the fault memory. For interrogation use the vehicle diagnostic, testing and information system VAS 5051 A or the vehicle diagnostic and service information system VAS 5052.
Note
- The procedure for performing self-diagnosis with the vehicle diagnostic, testing and information system VAS 5051 A is described in this Workshop Manual.
- After evaluating the information, the control unit differentiates between sporadic and static (currently present) faults and stores them in the memory.
- When a fault occurs, it is stored as a static (currently present) fault. If the fault does not occur again for a a predetermined period or distance travelled, the fault will then be reclassified as a sporadic fault.
- Sporadically occurring faults are displayed as “sporadic” when interrogating the fault memory.
- A fault also becomes "sporadic" when the ignition is switched off and on during interrogation or when the fault memory is not erased after repairs.
- When sporadic faults do not occur again they are automatically erased after 40 gearbox cold start cycles (ATF temperature below 71 °C) followed by gearbox warm-up (increase of ATF temperature by at least 21 °C).
- Inoperative CAN bus signals will be detected by the control unit. Defective CAN bus wiring, e.g. open circuits, cannot be directly detected. Conclusions as to where the CAN bus wiring is defective are not possible, until all control unit fault memories have been interrogated.