Checking
- Make
- Audi
- Model
- A6 C6
- Year
- 2004–2011
- Section
- Checking cooling output of air conditioner › Checking
Checking
Test requirements satisfied → Chapter
Measure ambient temperature (must be above 15 °C).
Close doors, bonnet, windows and sun roof.
Open all dash panel vents.
Switch on ignition.
Set “Econ” mode on the operating and display unit, Climatronic control unit J255 of “Basic” type (or deactivate “A/C” mode).
Set “Econ” mode on vehicles with an operating and display unit, Climatronic control unit J255 of “Convenience” type by pressing the “Econ” button or by way of the rotary knob/pushbutton of the MMI operating unit Owner's manual and Operating instructions for “Infotainment / MMI” (or deactivate “A/C” mode).
Note
- “Econ” or “A/C” mode is active when the lamp in the corresponding button is lit.
On vehicles with an air conditioner of “Convenience” type, close the vents in the “B” pillars.
On the MMI terminal, set the temperature for the adjustable centre vent to “Warm” (on vehicles with an air conditioner of “Convenience” type).
Start the engine.
Start air conditioner guided fault-finding "Guided fault-finding" function of vehicle diagnostic, testing and information system VAS 5051.
In the “Reading measured value block” function, select the display group with the following values (actuation of the air conditioning system compressor regulating valve N280 and measured value of the refrigerant pressure/temperature sender G395) and check the display "Guided fault-finding" function of vehicle diagnostic, testing and information system VAS 5051.
- Actuation of the compressor via the air conditioning system compressor regulating valve N280 deactivated (compressor switched off, display in display zone 0%)
- Pressure in the refrigerant circuit transmitted by the refrigerant pressure/temperature sender G395; equal to or greater than the value in the table below at the measured ambient temperature
| Ambient temperature in °C | Pressure display (in bar absolute) |
|---|---|
| 15 | 4,7 |
| 20 | 5,6 |
| 25 | 6,6 |
| 30 | 7,6 |
| 35 | 8,8 |
Note
- At absolute pressure, 0 bar corresponds to an absolute vacuum. Normal ambient pressure thus corresponds to roughly 1 bar absolute. On the scales of most pressure gauges, 0 bar corresponds to an absolute pressure of one bar (can be seen from -1 mark below 0).
- Pressure in refrigerant circuit is governed by ambient temperature. Due to heat emitted by components (e.g. radiator), pressure displayed with warm engine is slightly higher than that indicated for the relevant ambient temperature.
- If the pressure displayed is lower than that indicated in the table, check the signal of the refrigerant pressure/temperature sender G395"Guided fault-finding" function of vehicle diagnostic, testing and information system VAS 5051. If no fault is found at G395, there is not enough refrigerant in the circuit. The vehicle is to be taken to a workshop equipped with the necessary tools where the work can be performed by appropriately qualified personnel Air conditioner with refrigerant R134a.
- If pressure in refrigerant circuit is OK:
Switch on compressor (to do so, select “Auto” mode on operating and display unit, Climatronic control unit J255 of “Convenience” type or deactivate “Econ” function with “Basic” type).
Select “Lo” temperature (for driver's and front passenger's side) on operating and display unit, Climatronic control unit J255 of “Convenience” type or set lowest possible temperature with “Basic” type.
Set the air outflow direction on the operating and display unit, Climatronic control unit J255 to “dash panel vents”.
With operating and display unit, Climatronic control unit J255 of “Basic” type, check rotary fresh-air blower speed control; this must be set to position “A” (automatic regulation of fresh-air blower speed).
Select the “Reading measured value block” function "Guided fault-finding" function of vehicle diagnostic, testing and information system VAS 5051.
Check diagnosis tester display in the various display zones:
The display zone for actuation of the air conditioning system compressor regulating valve N280 shows a duty cycle greater than 30% ( N280 actuated, compressor switched on).
The display zone for the current to the air conditioning system compressor regulating valve N280 shows a current greater than 0.3 A (current flowing via N280, compressor switched on).
The pressure measured by the refrigerant pressure/temperature sender G395 and displayed increases above the value with the compressor switched off.
Note
- The air conditioning system compressor regulating valve N280 is actuated by the operating and display unit, Climatronic control unit J255 such that the temperature of the air downstream of the evaporator reaches the specified value (approx. 2 to 5 °C).
- After starting the vehicle, a value greater than 75 % (0.55 A) is displayed depending on the measured temperature, engine speed and electrical system voltage.
- As soon as temperature measured by evaporator outflow temperature sender G263 approaches specified value, actuation of air conditioning system compressor regulating valve N280 is cancelled and compressor output thus reduced.
- Connectors to air conditioning system compressor regulating valve N280 and electric engine mounting are identical. If the connectors are interchanged, no entry is made in the fault memory, but the evaporator may ice up as the compressor is constantly actuated (by the engine control unit).
- If no or an insufficient current is displayed in the display zone for actuation of the air conditioning system compressor regulating valve N280, check actuation of N280.
- If the pressure measured by the refrigerant pressure/temperature sender G395 and displayed does not change and if actuation of the compressor is OK, check whether the compressor is actually being driven (an overload safeguard is fitted between the compressor and the pulley / drive unit; if this has been tripped, the compressor is not driven). If no fault can be found, there is a problem with the refrigerant circuit. The vehicle is to be taken to a workshop equipped with the necessary tools where the work can be performed by appropriately qualified personnel Air conditioner with refrigerant R134a (there may be problems with compressor control). Inform the workshop of the problems encountered.
Press “recirculated-air mode” button on operating and display unit, Climatronic control unit J255 (symbol for “recirculated-air mode” in button lights).
Set engine speed to 2000 rpm (start of time measurement).
In the “Reading measured value block” function, select the display group with the measured value of the evaporator outflow temperature sender G263"Guided fault-finding" function of vehicle diagnostic, testing and information system VAS 5051.
Compare the measured value displayed (for G263) to the values in the graph.

Depending on ambient temperature, air temperature measured at evaporator outflow temperature sender G263 must be within stated tolerance range after 5 minutes.
Note
- If the required values are not attained, check the measured value of the evaporator outflow temperature sender G263, the left vent temperature sender G150 and the right vent temperature sender G151 and compare the measured values displayed "Guided fault-finding" function of vehicle diagnostic, testing and information system VAS 5051.
- If the measured values for G150 and G151 only differ slightly from the measured value for G263"Guided fault-finding" function of vehicle diagnostic, testing and information system VAS 5051, perform "Measures to be taken if readout does not match specification" Chapter.
- If the measured value for G263 is greater than the measured value for G150 and G151, check for proper installation of G263 and perform the electrical checks for this sender "Guided fault-finding" function of vehicle diagnostic, testing and information system VAS 5051.
- Operation of air conditioner can be established, for example, from cooling down of refrigerant pipe on low pressure end (thick pipe).
If the measured value for G263 (and thus the air conditioner cooling output) is OK:
Compare the measured value displayed for the evaporator outflow temperature sender G263 to the measured values for the left vent temperature sender G150 and the right vent temperature sender G151.
After 5 minutes, the measured values for G150 and G151 may be max. 3 °C higher than the measured value for the evaporator outflow temperature sender G263.
Note
- If the required values are not attained, compare the measured values displayed for G150, G151 and G263. If the measured value for G150 and / or G151 is not OK, check actuation and operation of the left heat regulation valve N175, the right heat regulation valve N176 and the coolant circulation pump V50Chapter and "Guided fault-finding" function of vehicle diagnostic, testing and information system VAS 5051.
- If no fault is found at the left vent temperature sender G150, the right vent temperature sender G151, the left heat regulation valve N175, the right heat regulation valve N176 and the coolant circulation pump V50, perform the "Measures to be taken in the event of temperature increase downstream of evaporator" Chapter and "Guided fault-finding" function of vehicle diagnostic, testing and information system VAS 5051.
- If the measured value for one or both senders ( G150 and / or G151) is lower than the measured value for the evaporator outflow temperature sender G263, check G263, G150 and G151 for proper installation and contact resistance in the electrical connections. Replace the defective sender if applicable → Chapter and "Guided fault-finding" function of vehicle diagnostic, testing and information system VAS 5051.
- The temperature of the air emerging from the “centre” dash panel vents can be measured using a commercially available thermometer for example (depending on vehicle equipment, it can also be read out in the measured value block) "Guided fault-finding" function of vehicle diagnostic, testing and information system VAS 5051.
- If the air emerging from the adjustable centre vent (only fitted with an air conditioner of “Convenience” type, in “Lo” setting or with the rotary temperature control on the “cold” stop for the driver's and front passenger's side on the operating and display unit, Climatronic control unit J255) is colder in the MMI “cold” setting for the adjustable centre vent than in the “warm” setting, check operation of the left heat regulation valve N175 and the right heat regulation valve N176"Guided fault-finding" function of vehicle diagnostic, testing and information system VAS 5051.
- If cooling output on one side (e.g. driver's side) is still adequate, but values are no longer attained on other side (e.g. front passenger's side), this is an indication of insufficient refrigerant in refrigerant circuit (stratification in evaporator due to lack of refrigerant).
Problems relating to differences between the temperature of the air emitted from the vents with an identical setting in air conditioner control mode may be due to the following:
- Cold or warm air flaps in air ducts not closing fully or not attaining end position "Guided fault-finding" function of vehicle diagnostic, testing and information system VAS 5051
- Air in heat exchangers (different flow on either side of heat exchanger and uneven heat distribution)
- Detachment of foam seal on heat exchanger installation, allowing air to flow past heat exchanger
Possible causes of problems which may occur even though cooling output is OK:
Repeated or sporadic failure of air conditioner (no cooling/heat output) after a long journey; air conditioner functions properly again after a short delay following engine shutoff.
Misting up of the windows on the inside after a long journey; the windows are initially not cleared even by pressing the “Defrost” button; the air conditioner functions properly again after a short delay following engine shutoff.
Under certain operating conditions residual moisture in the coolant circuit may lead to the formation of ice at air conditioning system compressor regulating valve N280. Such ice formation impairs compressor control, the evaporator is cooled excessively and ices up. Icing-up of the evaporator may be the cause of these problems .
- Remedy:
Check the measured value of the evaporator outflow temperature sender G263 by way of the “Reading measured value block” function "Guided fault-finding" function of vehicle diagnostic, testing and information system VAS 5051.
If sender measured value is too high under usage conditions described by customer (greater than e.g. 10 °C although air conditioner is functioning properly), check evaporator outflow temperature sender G263 (incorrect measured value can cause evaporator to ice up).
If the sender measured value is too low under the usage conditions described by the customer (colder than 0 °C for a lengthy period at an ambient temperature greater than 0 °C), there is a fault in the refrigerant circuit. Take the vehicle to a workshop equipped with the necessary tools where the work can be performed by appropriately qualified personnel Air conditioner with refrigerant R134a.
Check refrigerant pipe between evaporator and reservoir (thick pipe, low-pressure end) with engine running. If this pipe is severely iced up when the problem occurs (a thin ice layer is permissible), this is also an indication that the temperature in the evaporator is too low. Take the vehicle to a workshop equipped with the necessary tools where the work can be performed by appropriately qualified personnel Air conditioner with refrigerant R134a (compressor control may not be OK). Inform the workshop of the problem encountered. The necessary work can only be performed by such specialists (draining of refrigerant circuit, replacement of reservoir and subsequent evacuation of refrigerant circuit for at least 3 hours).
Parts & tools for this job For 2004 Audi A6
- TOOLA/C manifold gauge setSearch: AC manifold gauge set
- TOOLUV leak detection kitSearch: AC UV leak detection kit
- PARTCabin filterSearch: Audi A6 2004 cabin filter
As an Amazon Associate we earn from qualifying purchases.