Cleaning injectors
- Make
- Audi
- Model
- A6 C6
- Year
- 2004–2011
- Section
- Injection system › Cleaning injectors
Cleaning injectors
Special tools and workshop equipment requiredUltrasonic cleaning unit VAS 6418Mounting plate for injection modules VAS 6418/1Cleaning fluid VAS 6418/2Remove injectors → Chapter.
Note
- Observe safety precautions and operating instructions for ultrasonic unit.
Ultrasonic unit must be filled with cleaning fluid VAS 6418/2.
Note
- Ultrasonic unit must be filled with cleaning fluid up to top edge of apertures (see detail in illustration).

Insert injectors (1) all the way into mounting plate for injection modules VAS 6418/1(2); injectors will then be immersed in cleaning fluid.

Set rotary knob (4) to a temperature of 50°C.
Select a cleaning time of 30 minutes with rotary knob (5).
Switch on ultrasonic unit with button (3).
Note
- The time set starts to elapse as soon as a cleaning temperature of 50°C is reached.
After cleaning, always renew combustion chamber ring seal (teflon ring seal) for each injector → Chapter.
Then re-install injectors → Chapter.
Parts & tools for this job For 2004 Audi A6
- PARTFuel filterSearch: Audi A6 2004 fuel filter
- TOOLFuel pressure test kitSearch: fuel pressure test kit
- TOOLFuel line disconnect toolSearch: fuel line disconnect tool