A6 C6 (2004-2011): Heating and air conditioning: Auxiliary Heater
Also for this vehicle: A6 Quattro Sedan (4F2) V8-4.2L (BVJ) (2011), A6 Quattro Sedan V6-2.7L Turbo (APB) (2000), A6 Quattro Sedan V6-2.8L (AFC) (1995), A6 Quattro Sedan V6-2.8L (AHA) (1998), A6 Quattro Sedan V6-3.0L (AVK) (2002), A6 Quattro Sedan V6-3.0L SC (CCAA) (2010), A6 Quattro Sedan V6-3.2L (BKH) (2005), A6 Quattro Sedan V8-4.2L (ART) (2000), A6 Quattro Sedan V8-4.2L (BVJ) (2007), A6 Quattro Wagon V6-2.8L (AFC) (1995), A6 Quattro Wagon V6-3.0L (AVK) (2002), A6 Quattro Wagon V6-3.0L SC (CCAA) (2010), A6 Quattro Wagon V6-3.2L (BKH) (2006), A6 Sedan (4F2) V6-3.2L (CALA) (2011), A6 Sedan V6-2.8L (AFC) (1995), A6 Sedan V6-2.8L (AHA) (1998), A6 Sedan V6-2.8L (ATQ) (2000), A6 Sedan V6-3.2L (BKH) (2007), A6 V6-3.0L (AVK) (2004), A6 Wagon V6-2.8L (AFC) (1995), A6 C5 (1997-2004), A6 C7 (2011-2018).
Choose Sections to see everything in a chapter, or a chapter title to start at its first page.
Engine
Transmission
Steering and suspension
Brakes
Electrical
Heating and air conditioning
- 53Heating and air conditioning: Auxiliary HeaterHeating and air conditioning: Auxiliary Heater: Sections
- Safety precautions when working on vehicles fitted with auxiliary heater › Safety precautions when working on vehicles fitted with auxiliary heater
- Notes on general repair work on vehicles fitted with auxiliary heater › Notes on general repair work on vehicles fitted with auxiliary heater
- Rules for cleanliness when working on auxiliary heater › Rules for cleanliness when working on auxiliary heater (and fuel system)
Layout of components for auxiliary heater in vehicle6 pages
- Layout of components for auxiliary heater in vehicle
- Buttons and indicator lamps of auxiliary heater remote control
- Telestart “T90” / “T91” remote control hand transmitter version
- Checking and replacing batteries in auxiliary heater remote control hand transmitter
- Adaption of remote control hand transmitter in auxiliary heater control unit J364
- Activating/deactivating auxiliary heater/auxiliary ventilation via Multi Media Interface (MMI)
Diverting fuel for auxiliary heater16 pages
- Diverting fuel for auxiliary heater
- Components for diverting fuel for auxiliary heater
- Fuel diversion components (all models except Audi S6)
- Filling fuel pipe to metering pump V54 with fuel (bleeding)
- Fuel diversion components (Audi S6)
- Routing of auxiliary heater fuel-diverting hose in fuel delivery unit
- Removing and installing metering pump V54
- Checking operation of fuel shut-off valve N109
- Routing the fuel pipe to the auxiliary heater
- Routing of fuel pipe (all models except Audi S6)
- Routing of fuel pipe (Audi S6)
- Checking fuel delivery of metering pump V54
- Test conditions and preliminary work
- Filling fuel pipe completely
- Checking delivery rate
- Checking fuel delivery of metering pump V54 with auxiliary heater switched on
Checking and adjusting CO2 content in auxiliary heater exhaust gas24 pages
- Checking and adjusting CO2 content in auxiliary heater exhaust gas
- Checking CO2 content in auxiliary heater exhaust gas
- Adjusting CO2 content in auxiliary heater exhaust gas
- Adjusting
- Checking electrical connections to auxiliary heater and circulation pump V55
- Required measuring and testing equipment:
- Test conditions
- Checking auxiliary heater actuation and electrical connections (all models except Audi S6)
- Checking auxiliary heater actuation and electrical connections (Audi S6)
- List of electrical tests.
- Test step 1 (power supply and earth connection)
- Test step 2 (connection from auxiliary heater to metering pump V54)
- Test step 3 (connection from auxiliary heater to coolant shutoff valve N279)
- Test step 4 (connection from auxiliary heater to fuel pump relay for additional heater J749 or to relevant engine contro
- Test step 5 (connection between auxiliary heater and circulation pump V55)
- Checking auxiliary heater components
- Measuring instruments and test equipment required
- Preparation for testing
- List of electrical tests.
- Test step 1 (glow plug with flame monitor Q8)
- Test step 2 (overheating fuse S24 / overheating sensor G189 and temperature sensor G18)
- Characteristic resistance curve of overheating fuse S24 / overheating sensor G189
- Characteristic resistance curve of temperature sensor G18
- Test step 3 (fuel pre-heating heater element Z66 and fuel shut-off valve N109)
Functional description of auxiliary heater9 pages
- Functional description of auxiliary heater
- Functional description of auxiliary heater
- Prerequisites for sequence described on the following pages (when switching on heater):
- Control sequence when starting the auxiliary heater (also as additional heater)
- Auxiliary heater components
- Control sequence when starting the auxiliary heater (also as additional heater)
- Auxiliary heater control sequence on load change (from full to part-load mode and vice versa)
- Control sequence on shutoff of auxiliary heater
- Auxiliary heater temperature control curve
Incorporation of auxiliary heater into coolant circuit8 pages
- Incorporation of auxiliary heater into coolant circuit
- Incorporation of auxiliary heater on vehicles with heater coolant shutoff valve N279
- Operation and actuation of heater coolant shutoff valve N279
- Removing and installing heater coolant shutoff valve N279
- Removing and installing heater coolant shut-off valve N279 (all models except Audi S6)
- Removing and installing heater coolant shut-off valve N279 (Audi S6)
- Actuation of circulation pump V55 in auxiliary heating mode
- Bleeding coolant circuit
Dismantling and assembling auxiliary heater17 pages
- Dismantling and assembling auxiliary heater
- Detaching add-on components from auxiliary heater/re-attaching (all models except Audi S6)
- Removing and installing circulation pump V55
- Removing and Installing intake air silencer
- Removing and installing auxiliary heater silencer with corrugated exhaust pipes
- Detaching add-on components from auxiliary heater/re-attaching (Audi S6)
- Removing and installing circulation pump V55
- Removing and installing intake air silencer
- Removing and installing exhaust silencer with corrugated exhaust pipes
- Dismantling and assembling auxiliary heater
- Design of auxiliary heater control unit J364 and combustion air blower V6
- Checking installation position of glow plug with flame monitor Q8
- Attaching connection for coolant hoses to auxiliary heater
- Removing and installing combustion air intake pipe
- Assembling burner housing with heat exchanger and outer casing
- Assembling auxiliary heater control unit J364 and burner element
- Removing and installing overheating fuse S24 / overheating sensor G189 and temperature sensor G18